Operating Instructions Part 2

MDS 05-3624A01, Rev. B OEM Series I/O Guide 29
4. Apply a steady signal to the radio at the programmed receive
frequency (80 dBm level recommended; no stronger than 60
dBm). This can be done with a signal generator or an over-the-air
signal.
5. Measure the radios RSSI using a terminal interface. See
Section 4.0, TRANSCEIVER PROGRAMMING on Page 14.
6. With a non-metallic tool, carefully adjust each section of the helical
lter for maximum RSSI. Repeat several times to work out any
interactions. Re-install the cover to the transceiver.
Invisible place holder
Figure 14. Helical Filter Location
(Shield cover removed)
6.4 Upgrading the Radios Software
From time to time, new product features or software maintenance files
become available from MDS. This section describes the steps necessary
to install new software into the transceiver using a PC connected to the
radios
DATA INTERFACE port.
When software upgrades become available, they can be obtained on the
MDS Web site at www.microwavedata.com, or you can contact MDS
to request radio software.
NOTE: Software upgrades are distributed as ASCII files with a .S28
extension. These files use the Motorola S-record format.
HELICAL
ADJUSTMENTS
HELICAL
ADJUSTMENTS