Operating Instructions Part 2
Table Of Contents
MDS 05-3624A01, Rev. B OEM Series™ I/O Guide 21
• PWR is set to H [+37 dBm (5 watts)]
• RXTOT is set to NONE
• TOT is set to OFF
All other commands stay at their previously established settings.
KEY
This command activates the transmitter. The transmitter stays keyed
until either the DKEY command is entered, or the transmitter time-out
timer is enabled and times out. See also the
DKEY and TOT commands.
NOTE: The KEY and DKEY commands are not intended for normal
operation. They are tools for field testing and installation.
OWM [XXX...]
This is a command to display or set an owner’s message. To program
the owner’s message, type
OWM then the message, followed by .
The maximum number of characters that can be entered is 30.
To display the owner’s message, type OWM then . The owner’s
message appears on the display.
OWN [XXX...]
This is a command to display or set an owner’s name. To program the
owner’s name, type
OWN then the name, followed by . The
maximum number of characters that can be entered is 30.
To display the owner’s name, type OWN then . The owner’s
name appears on the display.
PWR [L | M | H]
NOTE: This function may not be available, depending on certification
requirements for a particular region.
This command displays or sets the desired RF forward output power
setting of the radio. The
PWR command parameter is specified as
L (low), M (medium), or H (high). The default setting is H. The values of
L, M, and H are:
L = 24 dBm (250 mW)
M = 30 dBm (1 W)
H = 37 dBm (5 W)
ENTER
ENTER
ENTER
ENTER