Operating Instructions Part 2

MDS 05-3624A01, Rev. B OEM Series I/O Guide 21
PWR is set to H [+37 dBm (5 watts)]
RXTOT is set to NONE
TOT is set to OFF
All other commands stay at their previously established settings.
KEY
This command activates the transmitter. The transmitter stays keyed
until either the DKEY command is entered, or the transmitter time-out
timer is enabled and times out. See also the
DKEY and TOT commands.
NOTE: The KEY and DKEY commands are not intended for normal
operation. They are tools for field testing and installation.
OWM [XXX...]
This is a command to display or set an owners message. To program
the owners message, type
OWM then the message, followed by .
The maximum number of characters that can be entered is 30.
To display the owners message, type OWM then . The owners
message appears on the display.
OWN [XXX...]
This is a command to display or set an owners name. To program the
owners name, type
OWN then the name, followed by . The
maximum number of characters that can be entered is 30.
To display the owners name, type OWN then . The owners
name appears on the display.
PWR [L | M | H]
NOTE: This function may not be available, depending on certification
requirements for a particular region.
This command displays or sets the desired RF forward output power
setting of the radio. The
PWR command parameter is specified as
L (low), M (medium), or H (high). The default setting is H. The values of
L, M, and H are:
L = 24 dBm (250 mW)
M = 30 dBm (1 W)
H = 37 dBm (5 W)
ENTER
ENTER
ENTER
ENTER