Operating Instructions Part 2

MDS 05-3624A01, Rev. B OEM Series I/O Guide 17
ACCESS DENIEDThe command is unavailable to the user. Refer to the
command descriptions for command information.
EEPROM FAILURE The INIT command was unable to write to EEPROM.
This usually indicates a hardware error. Contact MDS for assistance.
Table 5. Command summary
Command name Function
ADDR [NONE | 1255]
Details page 18
Set or display the network address of the radio.
AMASK [0000
0000FFFF FFFF]
Details page 18
Set or display hex code identifying which events
trigger an alarm.
BAUD [xxxxx abc]
Details page 19
Set or display the DATA INTERFACE data rate
and format.
CTS [0255]
Details page 19
Set or display the Clear-to-Send delay in
milliseconds.
CTSHOLD [060000]
Details page 19
Set or display the delay, in milliseconds, at the
end of a CTS line response; CTS Key operation
only.
DEVICE [DCE | CTS KEY]
Details page 20
Set or display the CTS options.
DKEY
Details page 20
Dekey the radio (transmitter OFF) following a
KEY command.
INIT
Details page 20
Set radio parameters to factory defaults.
KEY
Details page 21
Key the radio (transmitter ON). Provides a carrier
for testing.
OWM [XXX...]
Details page 21
Set or display the owners message.
OWN [XXX...]
Details page 21
Set or display the owners name.
PWR [L | M | H]
Details page 21
Set or display the transmit power setting.
RSSI and RSSI!
Details page 22
Display the Received Signal Strength Indication.
RX [xxx.xxx]
Details page 22
Set or display the receive frequency.
RXTOT [NONE | 1255]
Details page 22
Set or display the value of the receive time-out
timer.
SER
Details page 22
Display the radio serial number.
SREV
Details page 22
Display the software revision level.