Installation Manual
4-18 Front Panel Operation
MK-MAN-01 CarrierWave Digital Radio
The table below describes the alarms.
Alarm Name Severity Description
Payload Offline Critical The link to the far-end radio is down.
Modem Unlock Critical The Modem has not achieved lock
ODU: TX LO Unlock Critical The ODU is reporting the TX LO is not locked
ODU: RX LO Unlock Critical The ODU is reporting the RX LO is not locked
ODU: TX Disabled Critical The transmitter has been commanded to the
Off state by either iConductor or the Front
Panel interface
ODU: PwrLoop Unlock Critical The internal power control loop in the ODU is
not functioning correctly
ODU: DC Pwr Err Critical There is a problem with the DC supply to the
ODU
ODU: Comm Failure Critical The IDU is unable to communicate with the
ODU
Pwr Mgmt Timeout Major Problem with the Adaptive Power Control
Internal Temp High Major The internal temperature of the IDU is above
the allowable threshold.
Internal Temp Low Major The internal temperature of the IDU is below
the allowable threshold.
Tx Power Max Major The transmitter output power is set at its
maximum value