Installation Manual

3-28 Installation
MK-MAN-01 CarrierWave Digital Radio
3.7.2.5 Logging Into the IDU Using CarrierWave iConductor
TM
Use the following procedure to log into an IDU using CarrierWave iConductor
TM
:
1. On your desktop, click the Start button and select Programs. Then click on the MS-DOS
Prompt icon.
2. In the MS-DOS window, type ping xxx.xxx.xxx.xxx (where xxx.xxx.xxx.xxx represents the IP
address of the IDU) and press enter.
3. If the ping is successful, the following message will appear: Reply from xxx.xxx.xxx.xxx:
bytes=a. time=b ms, TTL=c. Refer to Figure 3-17 for an example of a ping. A successful
ping implies that the IDU and the PC can communicate with one another across an Ethernet
connection.
4. Close the MS-DOS prompt window.
5. Using the Windows Programs->CarrierComm->vX-XX->IC menu (or the appropriate menu or
icon), start up the iConductor
TM
application.
6. Select the IDU that you wish to login to from the drop-down menu (see Figure 3-18). If there
is not a network element for that IDU, simply select any IDU icon
Note: If there is not an IDU icon, one must be added. To add an IDU icon, use the
Network drop-down menu and select Add. Refer to IDU iConductor
TM
Online Help at
C:\Program Files\CarrierComm\help\TOC.html for additional information on how to add an
IDU.
7. Use the Network drop-down menu and select Connect (see Figure 3-19). In the IDU
Connect window, complete the following:
Verify the information in the IP Address field
Enter engineer in the User ID field
Enter the password assigned by the System Administrator in the Password field