MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 41
INIT
The INIT command is used to reset the radio’s operating parameters to the
factory defaults. This may be helpful when trying to resolve configura-
tion problems that may have resulted from the entry of one or more
improper command settings. If you are unsure of which command set-
ting may have caused the problem, this command allows you to get back
to a known working state.
Use of the
INIT command causes the changes shown in Table 8 to be
applied.
MODE [M, R, R-M]
The
MODE command sets or displays the operating mode of the radio. A
master radio is designated by an
M; a remote is designated by an R.
Table 8. Factory Default Values
Produced by INIT Command
Default Setting
Corresponding
Command
For all radios
Device operation DCE DEVICE DCE
RF output power 30 dBm (1 watt) PWR 30
CTS delay 0
(CTS is continuously
asserted)
CTS 0
DATA INTERFACE port 4800 baud
8 data bits
no parity
1 stop bit
BAUD 4800 8N1
Remote radios
Transmitter
test frequency
Per factory default TX xxx
Receiver
test frequency
Per factory default RX xxx
Master radios
Transmitter
test frequency
Per factory default TX xxx
Receiver
test frequency
Per factory default RX xxx
Skipped frequencies None (radio will hop
across all 1019
frequencies)
SKIP NONE
Hop time Normal (80 ms per hop) HOPTIME NORMAL
Simplex/duplex
operation
Half-duplex SIMPLEX OFF
Buffer mode Seamless data mode
enabled
BUFF ON