User Manual

User Reference and Installation Manual 3-24
MDS 5800 II
installed and properly grounded. If this is not the case, the same measurement can be made
between cable pin 1 (RET) and a convenient ground (such as an ac outlet third-wire ground).
5. Turn the -48 V dc supply off.
6. Plug the SDIDU
TM
power cable into the SDIDU
TM
front panel DC Power connector (DC
Input). Place the voltmeter probes on the cable connector screw terminal screw heads as
per step 2 above. Refer to Figure 3-12. Note that the MDS 5800 II SDIDU
TM
does not have
a power on/off switch. When DC power is connected, the digital radio powers up and is
operational. There can be up to 320 mW of RF power present at the antenna port. The
antenna should be directed safely when power is applied.
7. Turn on the -48 V dc power supply, and verify that the reading on the digital voltmeter is as
specified in step 3 above.
8. Turn the -48 V dc supply off.
9. Connect the SDIDU
TM
to the laptop computer, using a Cat-5 Ethernet cable or connect the
SDIDU
TM
to a computer network, using a Cat-5 Ethernet cable. Connect the Ethernet cable
to NMS 1 or 2 connector on the SDIDU
TM
front panel. Refer to Figure 3-13 for the SDIDU
TM
front panel connections.
Figure 3-12. SDIDU
TM
DC Power Cable Connector
Figure 3-13. MDS 5800 II-SB, 1+1 Protection: SDIDU
TM
Front Panel Connections
2 1