User Guide
Simon Security System
55
Option Settings
Access Code 1 None
Access Code 2 None
Access Code 3 None
Access Code 4 None
Access Code 5 None
Panic Code None
a.
System Access Codes
Type Default
a
Installer Settings
Opt. #
Function Default Delete Range Who Can
Change:
Installer
Settings
01 Panel Piezo Beeps (must be on for UL listed systems) On Off On/Off U1 U2 M
02 Panel Voice On Off On/Off U1 U2 M
03 Latchkey Option Off Off 12:00 Midnight -
11:59 PM
U1 U2 M
04 Primary Phone Number None None 26 digits U1
05 Secondary Phone Number None None 26 digits U1
06 Downloader Phone Number None None 26 digits U1
07 Account Number 00000 00000 0 - FFFFFFFFFF U1 U2
08 Phone Lock Off Off On/Off U1
09 Downloader Code 12345 12345 00000-99999 U1
10 Entry Delay
(must be 45 seconds for UL listed systems)
030 sec 005 sec 005-254 sec
030-254 if Option 69
is added
U1 U2
11 Exit Delay
(must be 60 seconds for UL listed systems)
060 sec 005 sec 005-254 sec
045-254 if Option 69
is added
U1 U2
12 Phone Mod 1 (must be 0 or 1 for UL listed systems) 0 0 0-3 U1
13 Phone Mod 2 00 00 00-10 U1
14 DTMF On Pulse On/Off U1 U2
15 No Activity Report Off Off 02-24 hrs U1 U2
16 Auto Phone Test (must be set to 001 for UL listed
systems)
Off Off 001-254 days U1 U2
17 Dialer Delay Off Off 005-254 sec
015-045 is Option 69
is added
U1 U2
18 Alarm Cancel 005 Off 005-255 min U1 U2
19 RF Timeout (SUPSYNC)
(must be set to 04 for UL 985 & 1635 Listed systems,
or 24 for UL 1023 Listed systems
12 hrs 02 hrs 02-24 hrs U1 U2
20 Manual Phone Test On Off On/Off U1 U2
21 Opening Reports Off Off On/Off U1 U2