¾To set Phone Mod 2, press:
Add—Option #—13—0, 1, 2, or 3—DONE.
¾
To reset Phone Mod 2 (return to default), press:
Delete—Option #—13—DONE.
Option 14: DTMF Dialing (Default = on)
Determines whether the panel uses DTMF (on) or pulse (off) for dialing programmed
phone numbers.
¾
To turn on DTMF Dialing, press:
Add—Option #—14—DONE.
¾
To turn off DTMF Dialing, press:
Delete—Option #—14—DONE.
Option 15: No Activity Time-out (Default = off)
Determines whether the panel sends a No Activity report to a central station or pager
when the programmed time period elapses (on), or if the feature is disabled (off).
No activity means control panel, remote handheld, and keychain touchpad buttons
have not be pressed and sensors have not been tripped within a specified period of
time (except sensors in group 25).
The time-out can be set from 02 - 24 hours. All entries must be 2 digits.
¾
To set No Activity Time-out, press:
Add—Option #—15—02 - 24—DONE.
¾
To turn off No Activity Time-out, press:
Delete—Option #—15—DONE.
Option 16: Auto Phone Test (Default = off)
Determines whether the panel automatically performs a periodic phone test (on) or not
(off).
The test interval can be from 001 - 254 days. Entries must be 3 digits. The time of day
the panel performs the test is determined by Option 72: Supervisory Time, which must
be turned on for this feature to work.
Note
For UL 1635 listed systems,
Auto Phone Test must be set
to 001 days.
¾To set Auto Phone Test, press:
Add—Option #—16—001 - 254—DONE.
¾
To turn off Auto Phone Test, press:
03 Alarms only Contact ID
04 Non-Alarms only SIA
05 Non-Alarms only Contact ID
06 Phone 1 failure SIA
07 Phone 1 failure Contact ID
08 Latchkey, No Activity, Phone Test, Openings, Closings,
Fail to Open/Close, AC Power Restorals/Failures
Pager
09 Same as setting 8 plus Alarms Pager
10 Alarms and Latchkey only (See Options 43 and 44 for
more details.)
Voice Event
Notification
Phone Mod 2
Setting # Content Format