User Guide

Installation Instructions Document No. 466-1574
9
*This type is not certified as a primary protection circuit for UL-list-
ed systems and is for supplementary use only.
§This type is required for UL-listed residential fire alarm applica-
tions.
‡This type has not been investigated by UL.
The arming levels are:
0 = Subdisarmed (used to bypass intrusion sensors which are active
24 hrs/day) Only the Master Access Code can enter this level
1 = Disarm
2 = Arm Doors & Windows
3 = Arm Motion Sensors
4 = Arm Doors/Windows & Motion Sensors
Delays:
I = Instant Delay (no delay, immediate alarm)
S = Standard Delay (alarm sounds after programmed entry delay
time)
F = Follower Delay (alarm sounds immediately if entry/exit delay is
not active, otherwise alarm sounds after programmed entry delay
time)
Table 3 Sensor Type Characteristics
Type
Name/Application Siren Type
Delay
Rest
oral
Super
visory
Active in
Levels
00
Fixed Panic: 24 hour audible fixed emergency button
Intrusion I No Yes 1234
01
Portable Panic: 24 hour audible portable emergency buttons
Intrusion I No No 1234
02
Fixed Panic: 24 hour silent fixed emergency buttons. Status light will not
blink.
Silent I No Yes 01234
03
Portable Panic: 24 hour silent portable emergency buttons. Status light
will not blink.
Silent I No No 01234
04
Fixed auxiliary: 24 hour auxiliary sensor, such as Pendant Panic
Emergency I No Yes 01234
05
Fixed Auxiliary: 24 hour emergency button. Siren shut off confirms CS
report
Emergency
I No Yes 01234
06
Portable Auxiliary: 24 hour portable auxiliary alert button
Emergency
I No No 01234
07
Portable Auxiliary: 24 hour portable auxiliary button. Siren shut off con-
firms CS report
Emergency
I No No 01234
08
Special Intrusion: such as gun cabinets and wall safes.
Intrusion I Yes Yes 1234
09
Special Intrusion: such as gun cabinets and wall safes.
Intrusion S Yes Yes 1234
10
Entry/Exit Delay: Entry/Exit Delay that require a standard delay time.
Chime
Intrusion S Yes Yes 24
13
Instant perimeter: Exterior doors and windows. Chime
Intrusion I Yes Yes 24
14
Instant Interior: Interior doors
Intrusion F Yes Yes 234
15
Instant Interior: Interior PIR motion sensors*
Intrusion F No Yes 234
16
Instant Interior: Interior doors
Intrusion F Yes Yes 34
17
Instant Interior: PIR motion sensors*
Intrusion F No Yes 34
19
Delayed Interior: interior doors that initiate a delay before going into
alarm*
Intrusion S Yes Yes 34
20
Delayed Interior: PIR motion sensors that initiate a delay before going
into alarm*
Intrusion S No Yes 34
21
Local Instant Interior: 24 hour local alarm zone protecting anything that
opens and closes. No Report
Intrusion I Yes Yes 1234
22
Local delayed interior: same as group 21, plus activation initiates a delay
before going into alarm. No report.*
Intrusion S Yes Yes 1234
23
Local instant Auxiliary: 24 hour local alarm zone protecting anything that
opens and closes.‡ No report
Emergency I Yes Yes 01234
24
Local Instant Auxiliary: 24 hour local alarm zone protecting anything that
opens and closes. Sirens shut off at restoral. No report.*
Emergency
I Yes Yes 01234
25
Local Special Chime: Notify the user when a door is opened. Sounds
emit from a local annunciator.* No report
Three
Beeps
I No Yes 01234
26
Fire: 24 hour fire, rate-of-rise heat, and smoke sensors§.
Fire I Yes Yes 01234
27
Lamp control or other customer feature.‡ No report
Silent I Yes Yes 01234
28
PIR motion sensor, sound sensor, or pressure mat.‡ No report
Silent I No Yes 01234
29
Auxiliary: Freeze and Water Sensors
Trouble
Beeps
I Yes Yes 01234
32
PIR motion sensor or sound sensor‡ No report
Silent I No No 01234
33
Supervised Wireless Siren (SWS)
Silent I Yes Yes 01234
34
Carbon Monoxide Alarm
Emergency I Yes No 01234