Door or window is closed, but the Control Panel voice
says it is open.
• Be certain the arrow on the magnet and the guide line on the
transmitter are aligned and are within 1/4’ of each other.
• The sensor tamper switch may be open if it is a crystal sensor.
Motion sensors go off continuously. Be sure the sensor is mounted on a solid surface and the viewing field
is free from sources of changing temperature.
Motion sensor does not respond to motion. • Make sure the battery is fresh and installed correctly. Wait 2
minutes after installing a new battery to test the sensor.
• Adjust the sensor mounting.
• Leave the area for 3 minutes, then retest.
• The environment is too hot or too cold. Outdoor sensors will
operate between 32° and 120°F.
• Dirt or dust may be causing the problem. Wipe the sensor with a
clean, damp cloth.
X-10 Modules*
All Lamp Modules or Siren not working.*
• Be sure the Control Panel transformer is plugged directly into an
outlet and that the outlet is not controlled by a wall switch.
• Possibly a bad transformer.
• House code was programmed incorrectly.
One Lamp Module or Siren is not working.* • Unplug nearby equipment which may be causing interference
(light dimmer switches, televisions, appliances with older
motors).
• Check that the switch on the lamp or appliance is turned on and
remains on.
• Make sure the lamp has a working bulb.
• Make sure the lamp or appliance is plugged into the Lamp/
Appliance Module, the Module is plugged into the outlet and the
outlet is not controlled by a wall switch.
• Make sure the House and Unit Codes are correct.
• Move the Module to a different outlet that is on the same phase
(branch) of the household electrical circuit as the Control Panel.
Time activated or sensor activated light not working.* • Make sure you have programmed the light to be activated by a
timer or sensor.
• Make sure the system clock is set.
• Make sure these functions have been enabled by pressing the
LIGHTS Time Activated/Sensor Activated
on the Control
Panel. They are enabled if the button is lit.
Table 23 Troubleshooting Guide
Problem Solution
* = Not Available with Basic Model