The Control Panel says, code name is XXXX (the new
4 digit access code).
To delete a code:
1. Press Delete from the Start menu.
2. Press the Access Code button. Continue pressing
the Access Code button until you hear the access
code to be deleted.
3. Press DONE.
The Control Panel says, code name is deleted.
Installing the System
Control Panel General Information
Do not install the Control Panel near a window or
door where it can be reached easily by an intruder.
Control Panels should be installed in locations where
they are most likely to be heard.
Metal objects, mirrors, and metallic wallpaper can
block signals sent by the wireless sensors. Make sure
there are no metal objects in the way when installing
the system.
The system will prompt you through programming
steps with beeps and voice messages. If you need
more time before proceeding, simply close the Con-
trol Panel cover until you are ready to continue.
When the cover is closed, the Control Panel is in the
operating mode. Each time you close the Control Pan-
el cover, a series of beeps (from the control panel pi-
ezo, hardwire internal siren, SWS, and the X-10
powerhorn) will indicate the system status:
• One beep indicates the system is disarmed
• Two beeps verify that Door/Window sensors are
armed.
• Three beeps verify that Motion Sensors are
armed.
• Four beeps verify that both Door/Window and
Motion sensors are armed.
The system cannot work without power. If the electri-
cal power fails and the Control Panel battery is weak
or dead, the system will not work.
Control Panel Specifications
Power Requirements: 9 VAC, 700 mA
Non-Chargeable Backup Battery: 9 VDC 1.2 AH
UltraLife Lithium. The battery will last 24 hours with
no AC if fully charged. Typical Life of 1 year.
Rechargeable Backup Batteries:
1. 7.2 VDC, 1 Ah 5/3 AAA Nickel Metal Hydride
The battery will last 30 hours with no AC
2. 7.2 VDC, 580 mAh AAA Nickel Metal Hydride
The battery will last 16-18 hours with no AC
Radio Frequency: 319.5 MHz + or - 140 kHz
Nominal Range: 500 feet, open-air receiving range
Operating Temperature Range: 32°-122 ° F (0°-
50° C)
Maximum Humidity: 85% relative humidity, non-
condensing
Auxiliary Power Output: Regulated & unregulated,
fused 12 VDC at 250 mA (maximum)
Installation Guidelines
Use the following procedure to mount the Control
Panel to the wall or wall studs, using the supplied
mounting hardware and the panel mounting holes.
Table 20 Arming Levels
Arming
Level
Description of Level
0 Bypasses 24 hour intrusion sensors (Master
Access Code Only)
1 Disarm the system
2 Arm Doors and Windows
3 Arm Motions
4 Arm Doors, Windows, and Motions