User Guide
Installation Instructions Document No. 466-1574
25
Installing a Rechargeable Battery
Plug the AC power transformer into an unswitched
outlet.
Connect the rechargeable battery (#34-051 or #34-
052) as shown below in 7 Option 49 must be turned
on in order for the charging circuit to be activated.
The rechargeable battery will be fully charged after
nine hours. The system will have a low battery report
when checking system status until the battery is fully
charged.
If a rechargeable battery needs replacing, the control
panel must be power-cycled in order for the new bat-
tery to become fully charged. To power-cycle the con-
trol panel do the following:
1. Unplug the AC power transformer and battery.
2. Plug in the AC power transformer.
3. Plug in the new rechargeable battery.
Figure 7. Rechargeable Battery Installation
Connecting the Phone Line to the
Control Panel
If the system will be monitored by a central monitor-
ing station, you must install an RJ-31X jack between
the telephone company (TELCO) block and the Con-
trol Panel. The jack must be located within 5 feet of
the Control Panel.
Installing an RJ-31X Jack
Install and wire the RJ-31X jack as shown in Figure 8.
Figure 8. RJ-31X Wiring Diagram
Connecting the Phone Line to the Con-
trol Panel
1. Plug one end of the phone cord (included with
the Control Panel) into the RJ-31X jack.
2. Plug the other end of the phone cord into the
Control Panel phone jack labeled TO LINE.
3. When looking at the back of the Control Panel,
the top block is used to connect the phone to the
Control Panel, and is labeled TO PHONE, the
bottom block is used to connect the Control
Panel to the wall phone jack, and is labeled TO
LINE.
8959G 30A .D S F
RECHARGEABLE BATTERY
BRN
GRY
GRN
RED
DEALER
CABLE
TELCO
PROTECTOR
BLOCK
WHITE OR YELLOW
BLACK
GREEN
GREEN
RED
RED
BLACK
WHITE OR YELLOW
SPLICE
SPLICE
PREMISES PHONE JACK
EXISTING
PHONE
LINE
PHONE CORD
TO PANEL
JACK LABELED
'TO LINE'
GREEN
RED
8988G05B.DS4