Option 37: Sensor Activated Light Lockout Stop
Time*
Add
enables sensor activated li
g
ht lockout sto
p
time.
The
p
anel will not turn on a li
g
ht, between the
p
ro-
g
rammed start time (o
p
tion 36) and the
p
ro
g
rammed
sto
p
time (o
p
tion 37), even if sensor activated li
g
hts
are on.
Both options must be programmed for this
option to work correctly.
Delete
disables sensor activated li
g
ht lockout sto
p
time. The
p
anel will turn on a li
g
ht activated b
y
a sen-
sor at all times if sensor activated li
g
hts are enabled.
Option 38: Auto Arm
Add
enables auto arm. An
y
sensor that re
q
uires resto-
ral and is o
p
en when the
p
anel is armed will automat-
icall
y
be b
yp
assed when the
p
anel is done
p
rotestin
g
.
The
p
anel will
p
rotest for 4 minutes, then auto arm.
Pressin
g
the ARM Doors & Windows button a second
time will sto
p
the control
p
anel
p
rotest and auto arm
the s
y
stem. Pressin
g
this button a third time will arm
with no entr
y
dela
y
. The
p
anel will
g
o into alarm if an
instant alarm sensor is o
p
ened durin
g
an exit dela
y
. A
sensor learned as t
yp
e 26 can never be b
yp
assed.
Delete
disables auto arm. An
y
sensor that re
q
uires
restoral and is o
p
en when the exit dela
y
ex
p
ires will
automaticall
y
be b
yp
assed. Bee
p
s indicatin
g
the arm-
in
g
level will sound four times when the control
p
anel
is armed and one time when the exit dela
y
ends. The
p
anel will
g
o into alarm if an instant alarm sensor is
o
p
ened durin
g
an exit dela
y
. A sensor learned as t
yp
e
26 can never be b
yp
assed.
Option 39: Siren Time Out
Add
p
ro
g
rams siren time out from 1 to 30 minutes.
The default siren time out is 4 minutes.
Delete
siren never time out.
Option 40: Trouble Beeps
Add
enables trouble bee
p
s. If there is a trouble condi-
tion, six bee
p
s will sound ever
y
minute. If the
p
anel is
armed, disarmed, or status is
p
ressed, the trouble
bee
p
s will sto
p
and then resume 4 hours later.
Trouble bee
p
s will be heard if:
• There is AC
p
ower failure.
• The CPU batter
y
is low.
• There is a sensor failure.
• There is sensor trouble.
• There is a fail to communicate
p
roblem.
• The no activit
y
timer has timed out. Trouble
bee
p
s will continue for 5 minutes and if the
p
anel
does not see activit
y
, the trouble bee
p
s will sto
p
and the
p
anel will call the CS to re
p
ort the no
activit
y
.
Delete
disables trouble bee
p
s, so that if a
p
roblem oc-
curs the control
p
anel will not notif
y
the owner with
trouble bee
p
s.
Option 41: Chime Voice
The
p
anel has two chime modes which ma
y
be en-
abled b
y
p
ressin
g
the a
pp
ro
p
riate button on the
p
anel.
CHIME Doors
Chime doors is a chime sound (two bee
p
s) that will be
emitted from the interior siren out
p
ut, the
p
anel siren,
SWS, and the X-10
p
owerhorn siren (if set to unit #9)
when a door/window sensor which is t
yp
e 10 or 13 is
activated. If there are no sensors learned as t
yp
e 10 or
13, this function will not be available. The
p
anel will
announce which sensor was tri
pp
ed if chime voice is
on and the sensor was o
p
ened while the
p
anel is dis-
armed.
CHIME Special Motion*
Chime s
p
ecial motion is a chime sound (three bee
p
s)
that will be emitted from interior siren out
p
ut, the
p
anel siren, SWS, and the X-10
p
owerhorn siren (if
set to unit #9) when a chime sensor that is t
yp
e 25 is
activated (the alarm state is sent to the
p
anel). If there
are no sensors learned as t
yp
e 25, this function will
not be available. The
p
anel will announce which sen-
sor was tri
pp
ed if chime voice is on and the sensor
was o
p
ened while the
p
anel is disarmed.
Add
enables chime voice. The
p
anel will announce
which chime sensor has been tri
pp
ed if the chime fea-
ture is enabled.
Delete
disables chime voice. The
p
anel will not an-
nounce which chime sensor has been tri
pp
ed even if
the chime feature is enabled.
Option 42: Speaker Level*
Add
sets s
p
eaker level to the hi
g
h voice level.
Delete
sets the s
p
eaker level to the low voice level.
* = Not Available with Basic Model