Manual

GE Energy
Datasheet
2A DLynx
TM
: Non-Isolated DC-DC Power Modules
3Vdc –14Vdc input; 0.6Vdc to 5.5Vdc output; 2A Output Current
June 24, 2013 ©2012 General Electric Company. All rights reserved. Page 17
Table 5. Recommended values of R
TUNE
and C
TUNE
to obtain
transient deviation of 2% of Vout for a 1A step load with
Vin=3.3V
Vo 2.5V 1.8V 1.2V 0.6V
Co
3x47μF 2x47μF 3x47μF
330μF
Polymer
R
TUNE
100 150 100 100
C
TUNE
18nF 10nF 18nF 68nF
ΔV