12V MicroTLynx
TM
12A: Non-Isolated DC-DC Power Modules
4.5Vdc –14Vdc input; 0.69Vdc to 5.5Vdc output; 12A Output Current
May 2, 2013 ©2013 General Electric Company. All rights reserved. Page 2
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations
sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.
Parameter Device Symbol Min Max Unit
Input Voltage All V
IN
-0.3 15 Vdc
Continuous
Voltage on SEQ terminal All V
SEQ
-0.3 V
IN
Vdc
Voltage on SYNC terminal All V
SYNC
-0.3 12 Vdc
Voltage on PG terminal All V
PG
-0.3 6 Vdc
Operating Ambient Temperature All T
A
-40 85 °C
(see Thermal Considerations section) -D version T
A
-40 105 °C
Storage Temperature All T
stg
-55 125 °C
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter Device Symbol Min Typ Max Unit
Operating Input Voltage All V
IN
4.5
14.0 Vdc
Maximum Input Current All I
IN,max
11.5 Adc
(V
IN
=4.5V to 14V, I
O
=I
O, max
)
Input No Load Current
(V
IN
= 10.0Vdc, I
O
= 0, module enabled) V
O,set
= 0.69 Vdc I
IN,No load
26 mA
(V
IN
= 12.0Vdc, I
O
= 0, module enabled) V
O,set
= 3.3Vdc I
IN,No load
60 mA
Input Stand-by Current All I
IN,stand-by
1.2 mA
(V
IN
= 12.0Vdc, module disabled)
Inrush Transient All I
2
t 1 A
2
s
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V
IN
=0 to 14V
,
I
O
=
I
Omax
; See Test Configurations)
All 70 mAp-p
Input Ripple Rejection (120Hz) All 45 dB
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of
sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum
safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating
of 15A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc
input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further
information.