User guide

GE
Data Sheet
12V Austin SuperLynx
TM
16A: Non-Isolated DC-DC Power Modules
10Vdc –14Vdc input; 0.75Vdc to 5.5Vdc output; 16A Output Current
May 7, 2013 ©2013 General Electric Company. All rights reserved. Page 17
Recommended Pad Layout
Dimensions are in millimeters and (inches).
Tolerances: x.x mm ± 0.5 mm (x.xx in. ± 0.02 in.) [unless otherwise indicated]
x.xx mm ± 0.25 mm (x.xxx in ± 0.010 in.)
Name Pin No. Function
ON/OFF 1 Remote On/Off Control
Vin 2 Positive Input Voltage
GND 4 Common Ground
Vout 5 Positive Output Voltage
TRIM 6 Output Voltage Trim
SENSE 7 Positive Remote Sense