Owner's manual

GE
Data Sheet
12V Austin MicroLynx
TM
5A: Non-Isolated DC-DC Power Modules
10Vdc –14Vdc input; 0.75Vdc to 5.5Vdc output; 5A Output Current
May 6, 2013 ©2013 General Electric Company. All rights reserved. Page 4
Electrical Specifications (continued)
Parameter Device Symbol Min Typ Max Unit
Dynamic Load Response
(dIo/dt=2.5A/μs; V V
IN
= V
IN, nom
; T
A
=25°C)
All V
pk
50
mV
Load Change from Io= 50% to 100% of Io,max;
Co = 2x150 μF polymer capacitors
Peak Deviation
Settling Time (Vo<10% peak deviation)
All t
s
50
μs
(dIo/dt=2.5A/μs; V
IN
= V
IN, nom
; T
A
=25°C)
All V
pk
50
mV
Load Change from Io= 100% to 50%of Io,max:
Co = 2x150 μF polymer capacitors
Peak Deviation
Settling Time (Vo<10% peak deviation)
All t
s
50
μs
General Specifications
Parameter Min Typ Max Unit
Calculated MTBF (I
O
=I
O, max
, T
A
=25°C) 5,677,000 Hours
Weight
2.8 (0.1)
g (oz.)