Tus neeg siv phau ntawv
VFD31EDSRWW
GE
®
Commercial 7.7 cu. ft. Capacity Electric Dryer with
Built-In App-Based Payment System, Coin Compatible*
*Coin accessories sold separately.
For answers to your GE Commercial Laundry product questions,
visit our website at www.geappliances.com/commerciallaundry.
Specification Revised 11/22
ELECTRIC DRYER RATING:
240V 5600W 24A 60Hz
208V 4400W 22A 60Hz
EXHAUST OPTION: 4-way rear, right,
left and bottom
CIRCUIT REQUIREMENTS: An individual,
properly-grounded branch circuit,
protected by a 30-amp circuit breaker or
a time-delay fuse, is required.
NOTE: Dryer wall outlet must be located
within 36" of service cord entry and
accessible when dryer is mounted in
position.
INSTALLATION INFORMATION:
For complete information, see installation
instructions packed with your dryer.
A reliable WiFi network is required.
A 6 ft. power cord is required and
sold separately. Order WX9X4 for the
3-prong power cord and WX9X20 for
the 4-prong power cord.
*
Please visit GEAppliances.com/
commerciallaundry to begin account
set up prior to unit delivery
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
85-3/5˝
Listed by
Underwriters
Laboratories
SPECIAL INSTALLATION REQUIREMENTS
ALCOVE OR CLOSET INSTALLATION:
- If your dryer is approved for installation in an
alcove or closet, it will be stated on a label on the
dryer back.
- The dryer MUST be exhausted to the outside.
- Minimum clearances between dryer cabinet and
adjacent walls or other surfaces are:
0" either side; 1" front, top and rear
- Closet doors must be louvered or otherwise
ventilated and must contain a minimum of 60 sq.
in. of open area equally distributed. If this closet
contains both a washer and a dryer, doors must
contain a minimum of 120 sq. in. of open area
equally distributed.
- No other fuel-burning appliance shall be installed
in the same closet with a gas dryer.
- The installation must conform with the local codes,
or in the absence of local codes, with the National
Electric Code and National Fuel Gas Code, ANSI
Z223 for gas dryers.
MINIMUM CLEARANCES OTHER THAN ALCOVE
OR CLOSET INSTALLATION:
- Minimum clearances to combustible surfaces are:
0" both sides; 1" rear
DRYER EXHAUSTING INFORMATION :
Use metal duct only, vertical and horizontal ducting.