Quick Specs

JVB67ABB - GE Profile
36" Telescopic Downdraft System
TM
Specification Revised 4/00
For answers to your Monogram,
®
GE Profile Performance Series,
GE Profile
or GE appliance questions, call
GE Answer Center
®
service, 800.626.2000.
R
Listed by
Underwriters
Laboratories
6" Round
Straight
3-1/4" x 10"
Straight
6"
90° Elbow
6"
45° Elbow
3-1/4" x 10"
90° Elbow
3-1/4" x 10"
45° Elbow
3-1/4" x 10"
to 6" Round
Transition
6" Round
to 3-1/4 x 10"
Transitions
90° Elbow
3-1/4" x 10"
Wall Cap
with Damper
6" Round
Roof Cap
6" Round
Roof Vent
Duct Pieces
Equivalent Length*
Duct Pieces
Equivalent Length*
1 ft. (per foot length)
1 ft. (per foot length)
15 ft.
9 ft.
16 ft.
5 ft.
24 ft.
7 ft.
5 ft.
20 ft.
12 ft.
21 ft.
27 ft.
20 ft.
24 ft.
SHOULD NOT EXCEED 100 EQUIVALENT FT.
*Equivalent length of duct pieces are based on actual test conducted by
GE Evaluation Engineering and reflect requirements for good venting
performance with a downdraft rated at 500 CFM
Venting Duct Information
Plan the Ductwork
1. This downdraft blower system is designed for use with 3-1/4 “ x 10”
ductwork (can be transitioned to 6” round). Two different discharge
directions are available with side-to-side adjustment for the
accurate alignment of ductwork.
2. For best performance: choose the ducting option which allows the
shortest length of ductwork and a minimum number of elbows and
transitions. Check location of floor joists, wall joists, wall studs,
electrical wiring or plumbing for possible interference.
Steps to Determine Flexible Ducting’s Equivalent length
1. Measure the actual amount of offset (Maximum 3” recommended).
The effect upon airflow is dependent upon the amount of offset.
2. Calculate the equivalent ducting allowances using:
(__in. offset) x (14 Ft. per inch)
=__Ft. equivalent length.
1. Ensure that the total equivalent length of ducting does not exceed the
maximum recommendation of 150 feet.
Left discharge
(as shipped)
Right
discharge