Installation Instructions
,QVWDOOWKHVKXWRȺYDOYHRQWKHQHDUHVWIUHTXHQWO\XVHGGULQNLQJZDWHUOLQH
1
SHUT OFF THE MAIN WATER SUPPLY
AND UNPLUG REFRIGERATOR
Turn on the nearest faucet
(
counterclockwise
)
long
enough to clear the line of water.
9
Drill a 1/4 hole in the wate r pipe
(
even if using a self-
piercing valve
)
, using a sharp bit.
R
emove any burrs
resulting from d rilling the hole in the pipe. Take care not
to allow water to dr ain into the drill. Failure to drill a
1/4 hole may result in reduced ice production or smalle r
cubes.
DRILL THE HOLE FOR THE VALVE
3
)DVWHQWKHVKXWRȺYDOYHWRWKHFROGZDWHUSLSHZLWK
the pipe clamp.
Tighten the clamp screws until the sealing washer
begins to swell.
NOTE: Do not overtighten or you may crush the
tubing.
NOTE: Commonwealth of Massachusetts Plumbing
Codes 248CM
R
shall be adhered to.
S
addle valves
are illegal and use is not permitted in Massachusetts.
Consult with your licensed plumber.
FASTEN THE SHUTOFF VALVE
4
7
FLUSH OUT THE TUBING
Turn the main water supply on
FRXQWHUFORFNZLVHDQGÀXVKRXWWKH
tubing until the water is clear.
6KXWWKHZDWHURȺDWWKHZDWHUYDOYH
after about one quart
(
1 liter
)
of water
KDVEHHQÀXVKHGWKURXJKWKHWXELQJ
6
CONN ECT THE TUBING TO T HE VALVE
Place the compression nut and ferrule
(
sleeve
)
for
copper tubing onto the end of the tubing and connect
LWWRWKHVKXWRȺYDOYH
Make sure the tubing is fully inserted into the valve.
Tighten the compression nut securely.
For plastic tubing from a GE
S
martConnect
R
efrigerator Tubing kit, insert the molded end of the
WXELQJLQWRWKHVKXWRȺYDOYHDQGWLJKWHQFRPSUHVVLRQ
nut until it is hand tight, then tighten one additional
turn with a wrench. Overtightening may cause leaks.
NOTE: Commonwealth of Massachusetts Plumbing
Codes 248CM
R
shall be adhered to.
S
addle valves
are illegal and use is not permitted in Massachusetts.
Consult with your licensed plumber.
S
addle-Type
6KXWRȺ9DOYH
Compression
Nut
S
martConnect
Tubing
Packing Nut
Outlet Valve
Ferrule
(
sleeve
)
5
ROUTE THE TUBING
R
oute the tubing between the cold water line and the
refrigerator.
R
oute the tubing through a hole drilled in the wall or
ÀRRUEHKLQGWKHUHIULJHUDWRURUDGMDFHQWEDVHFDELQHW
as close to the wall as possible.
NOTE:%HVXUHWKHUHLVVXȻFLHQWH[WUDWXELQJDERXW
feet
[
1.82 m
]
coiled into 2 turns of about 10
[
25 cm
]
diameter
)
to allow the refrigerator to move out from
the wall after installation.
INSTALLING THE WATER LINE (CONT.)
1
Choose a location for the valve that is easily acces sible.
It is best to connect into the side
of a vertical water pipe. When it is
necessar y to connect into a horizontal
water pipe, make the connection to the
top or side, rather than at the bottom,
WRDYRLGGUDZLQJRȺDQ\VHGLPHQWIURP
the water pipe.
CHOOSE THE VALVE LOCATION
2
Washer
Inlet End
Clamp
S
c rew
Vertical Cold
Water Pipe
S
addle-Type
6KXWRȺ9DOYH
Pipe Clamp