Specification Sheet
AZ45E09DAP
GE Zoneline
®
 Dry Air 25 Cooling and Electric Heat Unit with Corrosion Protection, 230/208 Volt
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES) 
For answers to your Monogram, GE Café
™
 Series, GE Profile
™
 Series or 
GE Appliances product questions, visit our website at geappliances.com 
or call GE Answer Center
®
 Service, 800.626.2000.
Specification Revised 7/16
ELECTRICAL WIRING
All wiring, including installation of receptacle, must  
be made in accordance with local electrical codes  
and   regulations.
NOTE: Aluminum wiring may pose special problems –  
consult a qualified electrician.
GRILLE OPTIONS 
Stamped Aluminum Grille – RAG60 
Exterior Architectural Louvers Durable Polycarbonate: 
RAG61 (Beige)  RAG63 (Dark Brown) 
RAG62 (Maple) 
Extruded Aluminum Architectural Grille – RAG67
RETROFIT KITS: 
RAK40 – Deflector Kit to adapt chassis for use with  
existing (non-GE) exterior louvered grilles.
DUCTED APPLICATIONS 
AZ45 and AZ65 Series can be used with ductwork to heat 
or cool more than one room. RAK6053 Duct Adaptor is 
applied to the top of case over the air discharge. RAK601B 
Duct Extension is applied to right or left of adaptor. 
Locally fabricated ductwork may be added to extend to 
maximum recommended straight distance of 
15 feet in one direction.
ELECTRICAL CONNECTION 
230/208 volt units may be plugged into a receptacle. 
See Architects and Engineers Design Data Manual for 
 electrical connection information including use of sub-base 
for direct connected units. Installation must comply with 
local electrical codes and regulations. 
Power connection kits are required on all Zoneline chassis.
MAXIMUM CORD EXTENSION
SIDE
VIEW
Inside
Room
 Cabinet
Outside
58
21
Grille
7-1/8
RAB71A = 16
RAB77A = 16-1/4
RAB71A = 20-7/8
RAB77A = 21
Room Air/Installation QSart
A
C
B
Zoneline RAC Wall Installation
WALL CASE DIMENSIONS
RAB71B WALL SLEEVE 
Heavy-gauge galvanized steel, with 
insulation.  
A – 42", B – 13-3/4", C – 16" 
Also available in 16" and 24" depths
RAB77B WALL SLEEVE 
 Molded SMC fiberglass-reinforced  
polyester compound.  
A – 42-1/8", B– 13-7/8", C – 16-1/4"
WALL OPENING DIMENSIONS 
Add 1/4" to A and C dimensions  
for all cut-outs. 
RAB71B 16-1/4" Min. H x 42-1/4" Min. W 
RAB77B 16-1/2" Min. H x 42-3/8" Min. W
AZ45/65 HEATER KW 
230/208 
VOLT
LINE CORD (P), DIRECT (D) AND SUB-BASE CONNECTED UNITS
7K/9K  12K/15K
Power 
Connection Kit
RAK315P 
RAK315D 
RAK204D15C
RAK320P 
RAK320D 
RAK204D20C
 RAK330P 
 RAK330D 
 RAK204D30C
RAK315P 
RAK315D 
RAK204D15C
RAK320P 
RAK320D 
RAK204D20C
RAK330P 
RAK330D 
RAK204D30C
Total Watts 2410/1990 3420/2830 4830/3990 2430/2020 3450/2860 4860/4020
Heater Watts 2400/1960 3400/2780 4800/3930 2400/1960 3400/2780 4800/3930
Heater BTU 8100/6600 11600/9400 16300/13400 8100/6600 11600/9400 16300/13400
Total Amps 10.5/9.6 14.9/13.6 21.0/19.2 10.6/9.7 15.1/13.8 21.2/19.3
Min Circuit 15 20 30 15 20 30
Recommended 
Protective 
Device
15 amp time-
delay fuse or 
breaker
20 amp time-
delay fuse or 
breaker
30 amp time-
delay fuse or 
breaker
15 amp time-
delay fuse or 
breaker
20 amp time-
delay fuse or 
breaker
30 amp time-
delay fuse or 
breaker