Quick Specs
AZ41E09EAB
GE
Zoneline
®
 Deluxe Series Cooling and Electric Heat Unit, 265 Volt
Specification Revised 9/15
For answers to your Monogram
®
, GE Profile
™ 
Series 
or GE
®
 Series appliance questions, visit our website  
at geappliances.com or call GE Answer Center
®
service, 800.626.2000.
ElEctrical Wiring 
All wiring, including installation of receptacle, must  
be made in accordance with local electrical codes  
and   regulations.
notE: Aluminum wiring may pose special problems –  
consult a qualified electrician.
grillE options 
Stamped Aluminum Grille – RAG60
Exterior Architectural Louvers Durable Polycarbonate:
RAG61 (Beige) RAG63 (Bittersweet)
RAG62 (Maple) RAG67 (Extruded Aluminum)
rEtrofit Kits: 
RAK901L – Wall Case Insulation for use with heat pumps. 
RAK40 – Deflector Kit to adapt chassis for use with  
existing exterior architectural louvered grilles.
DuctED applications 
4100 and 6100 series can be used with ductwork to heat or cool more than one room. 
RAK6052 Duct Adaptor is applied to top of case over air discharge/RAK601 Duct 
Extension is applied to right or left of adaptor. Locally fabricated ductwork may be 
added to extend to maximum recommended distance of 15 feet.
ElEctrical connEction 
230/208 volt units may be plugged into a receptacle. 265 volt units are provided 
with a junction box and require direct connection. (NEC Requires 265V Direct 
Connection) See Architects and Engineers Design Data Manual for electrical 
connection information including use of sub-base for direct connected units. 
Installation must comply with local electrical codes and regulations.
poWEr connEction Kits rEquirED on all ZonElinE chassis.
Wall casE DimEnsions maximum corD ExtEnsion (in inchEs)
SIDE
VIEW
Inside
Room
 Cabinet
Outside
58
21
Grille
7-1/8
RAB71A = 16
RAB77A = 16-1/4
RAB71A = 20-7/8
RAB77A = 21
Room Air/Installation QSart
DimEnsions anD installation information (in inchEs) 
265 Volt suB-BasE connEctED units
suB-BasE
poWEr 
connEction 
Kit
ElEctric  
hEatEr 
Watts
ElEctric  
hEat amps
min. circuit 
protEction 
(amps)
RAK204E15 RAK5172 2,550 10.3 15
RAK204E20 RAK5202 3,450 13.7 20
RAK204E30 RAK5302 5,000 19.6 30
A
C
B
Zoneline RAC Wall Installation
raB71 Wall slEEVE
Heavy-gauge galvanized steel, with insulation.  
A – 42", B – 13-3/4", C – 16"
raB77 Wall slEEVE
Molded SMC fiberglass-reinforced polyester 
compound.  
A – 42-1/8", B– 13-7/8", C – 16-1/4
Wall opEning DimEnsions
Add 1/4" to A and C dimensions for all cut-out size. 
RAB71 16-1/4" Min. H x 42-1/4" Min. W 
RAB71 available in 16", 24", 28" and 31" depths 
RAB77 16-1/2" Min. H x 42-3/8" Min. W