Specification
Installation Guidelines
1. The roof deck must be swept clean and be smooth and dry 
  before installation begins.
2. Tri-Flex® 15 underlayment is laid horizontally (parallel to eave),  
  starting at the bottom of the roof, with printed side up and with  
  4-inch side laps and 6-inch end laps. Side laps run with the flow  
  of water in a shingling manner.
3. Tri-Flex® 15 underlayment should not be used at slopes less 
  than 2:12, provided the slope is also acceptable to the primary 
  roof covering. On slopes of less than 4:12, Tri-Flex® 15 
  underlayment should be half-lapped a full 24 inches over the 
  underlying course, shingle style.
4. Tri-Flex® 15 underlayment is attached to the roof with roofing  
  nails or staples both having 1-inch diameter plastic/metal caps,  
  spaced at 8 inches on center (oc) on both side and end laps  
  in normal wind zones. In high wind zones or coastal applications,  
  double the fastening to 4 inches oc. In all cases fasten at  
  24 inches oc down the middle of the roll in the field of the roof.  
  Fasteners may be hand or machine applied. Staples without  
  caps cannot be used.
5. Where seams or joints require sealant or adhesive, use a high 
  quality, low solvent, asbestos free plastic roofing cement 
  meeting ASTM D4586 Type 1, Federal Spec SS-153 Type 1 
  (Asbestos Free). Consult your local GCP representative for 
  more details.
6. Install drip edge at eaves under underlayment and at rake over 
 underlayment.
7. Installation of the roof covering can proceed immediately  
  following underlayment application. Tri-Flex® 15 underlayment  
  cannot be used as a primary roof covering. The product is not  
  designed for permanent outdoor exposure. The installation of  
  the final roof covering should take place within 60 days.
8. For additional protection lay a single length of Tri-Flex® 15 
  underlayment vertically in valleys and on hips prior to installing 
  metal flashings (if used) and before installing horizontal  
  underlayment. Return Tri-Flex® 15 underlayment up all 
  abutments at least 12 inches (more in heavy snow areas). 
  Secure and trim to suit.
9. Prior to loading roofing materials on Tri-Flex® 15 underlayment  
  it is recommended that roof jacks, toe-boards or a storage 
  platform be secured to the underlying roof deck to prevent 
  slippage of stored materials on steep sloped roofs. See OSHA 
  Regulations (Standards – 29 CFR), Fall Protection Systems  
  Criteria and Practices – 1926.502.
10.Check local building code to ensure compliance in your area, as  
  local building codes may vary.
Code Approvals
• Complies with AC-188 Acceptance Criteria for Roof  
 Underlayments.
•  Meets the requirements of Florida Building Code, Approval 
•  Complies with ASTM E108/UL 790 for use in the installation of  
  Class A asphalt glass fiber mat shingles and Class C asphalt 
  organic felt or metal shingles
•  Meets ASTM D226 physical requirements of Type I and Type II
Precautions and Limitations
• Consistent with good roofing practice, always wear fall  
  protection when working on a roof deck.
•  Slippery when wet or covered by frost, debris or dust.
•  Do not fold over the roof edge unless the edge is protected by  
  a drip edge, gutter or other flashing material.
•  Check with the manufacturer of the metal roofing system for 
  any special requirements when used under metal roofing.  
  Do not install directly under roof coverings especially sensitive  
  to corrosion, such as zinc, without providing proper ventilation.
•  Do not install under copper, Cor-Ten®, or zinc metal roofing in  
  high altitudes or in the desert southwest. These roofs can reach  
  extremely high temperatures due to the low reflectivity, high  
  absorption, and high conductivity of the metals.
•  Provide proper roof insulation and ventilation to help reduce ice  
  dams and to minimize condensation.
•  Repair holes, fishmouths, tears and damage to produc t . Tri-Flex® 15 
  underlayment does not self-seal open fastener penetrations.
Used only capped nails or capped staples.
Lay with a minimum 6 inches end lap.
Use a 4 inch side lap. Follow printed 
guidelines for easy installation.
Fasten at 24 inches oc in the middle of the roll.