Before surface conditioner dries, tools should be cleaned with
water. After surface conditioner dries, tools should be cleaned
with mineral spirits. Mineral spirits is a combustible liquid which
should be used only in accordance with manufacturers recom-
mendations. Do not use solvents to clean hands or skin.
Corner Details
The treatment of corners varies depending on the location of the
corner. For detailed information on Bituthene
®
Liquid Membrane,
see separate product information sheet.
At wall to footing inside corners—
Option 1: Apply membrane to within 1 in. (25 mm) of base of
wall. Treat the inside corner by installing a
3
4
in. (20 mm) llet
of Bituthene
®
Liquid Membrane. Extend Bituthene
®
Liquid
Membrane at least 2
1
2
in. (65 mm) onto footing, and 2
1
2
in. (65
mm) onto wall membrane.
Option 2: Treat the inside corner by installing a
3
4
in. (20 mm)
llet of Bituthene
®
Liquid Membrane. Apply 12 in. (300 mm)
wide strip of sheet membrane centered over llet. Apply wall
membrane over inside corner and extend 6 in. (150 mm) onto
footing. Apply 1 in. (25 mm) wide troweling of Bituthene
®
Liquid Membrane over all terminations and seams within
12 in. (300 mm) of corner.
At footings where the elevation of the oor slab is 6 in. (150
mm) or more above the footing, treat the inside corner either
by the above two methods or terminate the membrane at the
base of the wall. Seal the termination with Bituthene
®
Liquid
Membrane.
Joints
Properly seal all joints with waterstop, joint ller and sealant as
required. Bituthene
®
membranes are not intended to function as
the primary joint seal. Allow sealants to fully cure. Pre-strip all
slab and wall cracks over
1
16
in. (1.5 mm) wide and all construc-
tion and control joints with 9 in. (230 mm) wide sheet membrane
strip.
Application on Horizontal Surfaces
(Note: Preprufe
®
pre-applied membranes are strongly recom-
mended for below slab or for any application where the
membrane is applied before concreting. See Preprufe
®
water-
proong membrane product information sheets.)
Apply membrane from the low point to the high point so that laps
shed water. Overlap all seams at least 2 in. (50 mm). Stagger all
end laps. Roll the entire membrane rmly and completely as soon
as possible. Use a linoleum roller or standard water-lled garden
roller less than 30 in. (760 mm) wide, weighing a minimum of 75
lbs (34 kg) when lled. Cover the face of the roller with a resil-
ient material such as a
1
2
in. (13 mm) plastic foam or two wraps
of indoor-outdoor carpet to allow the membrane to fully contact
the primed substrate. Seal all T-joints and membrane terminations
with Bituthene
®
Liquid Membrane at the end of the day.
Protrusions and Drains
Apply membrane to within 1 in. (25 mm) of the base of the
protrusion. Apply Bituthene
®
Liquid Membrane 0.1 in. (2.5 mm)
thick around protrusion. Bituthene
®
Liquid Membrane should
extend over the membrane a minimum of 2
1
2
in. (65 mm) and up
the penetration to just below the nished height of the wearing
course.
Vertical Surfaces
Apply membrane in lengths up to 8 ft (2.5 m). Overlap all seams
at least 2 in. (50 mm). On higher walls apply membrane in two or
more sections with the upper overlapping the lower by at least 2
in. (50 mm). Roll all membrane with a hand roller.
Terminate the membrane at grade level. Press the membrane
rmly to the wall with the butt end of a hardwood tool such as a
hammer handle or secure into a reglet. Failure to use heavy pres-
sure at terminations can result in a poor seal. A termination bar
may be used to ensure a tight seal. Terminate the membrane at the
base of the wall if the bottom of the interior oor slab is at least 6
in. (150 mm) above the footing. Otherwise, use appropriate inside
corner detail where the wall and footing meet.
Membrane Repairs
Patch tears and inadequately lapped seams with membrane.
Clean membrane with a damp cloth and dry. Slit shmouths and
repair with a patch extending 6 in. (150 mm) in all directions
from the slit and seal edges of the patch with Bituthene
®
Liquid
Membrane. Inspect the membrane thoroughly before covering
and make any repairs.
Drainage
Hydroduct
®
drainage composites are recommended for both
active drainage and protection of the membrane. See Hydroduct
®
product information sheets.
Protection of Membrane
Protect Bituthene
®
membranes to avoid damage from other
trades, construction materials or backll. Place protection imme-
diately in temperatures above 77°F (25°C) to avoid potential for
blisters.
On vertical applications, use Hydroduct
®
220 Drainage
Composite. Adhere Hydroduct
®
220 Drainage Composite to
membrane with Preprufe
®
Detail Tape. Alternative methods of
protection are to use 1 in. (25 mm) expanded polystyrene or
1
4
in. (6 mm) extruded