Full Product Manual

www.graceconstruction.com
For technical assistance call toll free at 866-333-3SBM (3726)
Vycor, Grace Ice & Water Shield and Perm-A-Barrier are registered trademarks of W. R. Grace & Co.–Conn.
DensGlass Gold is a registered trademark of Georgia-Pacic Corporation.
We hope the information here will be helpful. It is based on data and knowledge considered to be true and accurate
and is offered for the users’ consideration, investigation and verication, but we do not warrant the results to be
obtained. Please read all statements, recommendations or suggestions in conjunction with our conditions of sale,
which apply to all goods supplied by us. No statement, recommendation or suggestion is intended for any use which
would infringe any patent or copyright. W. R. Grace & Co.–Conn., 62 Whittemore Avenue, Cambridge, MA 02140.
In Canada, Grace Canada, Inc., 294 Clements Road, West, Ajax, Ontario, Canada L1S 3C6.
This product may be covered by patents or patents pending. Copyright 2014. W. R. Grace & Co.–Conn.
TP-073J Printed in U.S.A. 08/14 GCS/PDF
wood plank, metal, concrete or gypsum sheathing. Remove dust,
dirt and loose nails. Protrusions must be removed. Surfaces shall
have no voids, damaged or unsupported areas. Repair surfaces
before installing the membrane.
Priming is generally not required for most substrates provided they
are clean and dry. However, on concrete, masonry and DensGlass
Gold
®
, apply Perm-A-Barrier
®
WB Primer. If adhesion is found to
be marginal, also prime wood composition and gypsum sheathing
with Perm-A-Barrier WB Primer. The coverage rate for Perm-A-
Barrier WB Primer is 250–350 ft
2
/gal (6–8 m
2
/L).
Membrane Installation
Apply Grace Vycor V40 in fair weather when the air, surface and
membrane are at temperatures of 25°F (-4°C) or higher. After
precipitation, allow a minimum of 24 hours for drying before
installing the ashing.
Cut the membrane to appropriate length. Peel back the release
liner, align the membrane, press into place and rmly roll. Laps
must be a minimum of 3 in. (75 mm). Mechanically fasten
the membrane at vertical terminations. Consistent with good
construction practices, install Grace Vycor V40 such that all laps
shed water. The top membrane layer should go over the bottom
layer. Always work from the low point to the high point.
Precautions and Limitations
Grace Vycor V40 is designed for non-roof detail areas. This
product is slippery—DO NOT walk on the membrane.
Do not leave Grace Vycor V40 permanently exposed to sunlight.
Maximum recommended exposure is 30 days.
Grace Vycor V40 should not be used in hot desert areas in the
southwestern United States.
Due to its slight asphaltic odor, apply Grace Vycor V40
where it is not exposed to interior living space. The product is
incompatible with creosote, joint sealants containing polysulde
polymer, products manufactured from EPDM, exible PVC,
as well as certain caulks. Refer to Tapes Technical Letter 1,
Chemical Compatibility, for further details. Contact window
manufacturer for specic application instructions required when
using a self-adhering, bituminous-based ashing. Certain metal
window applications with integral nailing n may have specic
limitations. For more information, contact your local Grace
representative.
Warranty
Grace Vycor V40 is warranted at the time of shipment to meet
Grace’s published specications.
Approvals
Approved as a ashing material
(ICC ER-6141).
Property Grace Vycor V40
Product thickness 40 mil (1.02 mm)
Carrier lm Cross-laminated HDPE
Adhesive Rubberized asphalt
Release liner Paper
Color Black-Gray
Recommended
exposure limit
30 Days
Shrink Wrapped Rolls
Roll width(s) 6 in. (150 mm) 9 in. (225 mm) 12 in. (300 mm)
Roll length(s) 50 ft (15.2m) 50 ft (15.2m) 50 ft (15.2m)
Rolls per carton 12 6 6
Bulk Rolls
Roll width(s) 6 in. (150 mm) 9 in. (225 mm) 12 in. (300 mm) 18 in. (455 mm)
Roll length(s) 75 ft (22.9m) 75 ft (22.9m) 75 ft (22.9m) 75 ft (22.9m)
Rolls per carton 6 4 3 2
80