G VYCOR ® Self-Adhered Flashing Contractor’s Guide WINDOWS, DOORS AND DETAIL AREAS TM Flash it right. ® Install Grace Vycor Self-Adhered Flashing under, and call-backs are over.
What Self-Adhered Flashings Does Grace Offer? There are three key products offered by Grace to meet your flashing needs.
Why Use Grace Flashings on Windows, Doors and Other Critical Detail Areas TM Flash it right. Why Use Self-Adhered Flashing on Windows and Doors? • To protect windows, doors and other critical areas from water intrusion • To control water and moisture – the first step in controlling mold 1 Water damage is one of the most common causes of building repairs. Not only are such repairs costly, but in many cases damage is impossible to correct.
Where to Apply Grace Vycor Self-Adhered Flashings CRITICAL FLASHING AREAS n Grace Ice & Water Shield ® All of the shaded areas below can benefit from the application of Grace Vycor Self-Adhered Flashings (beneath the finished siding and decking) and Grace Underlayments (like Grace Ice & Water Shield) for the roof. Consider Grace Vycor SelfAdhered Flashings for your critical non-roof flashing details (windows, doors, decks).
Why Grace Vycor Plus TM Flash it right. WHY GRACE VYCOR PLUS? There are a number of flashing materials available on the market today. The major difference between them is the level of waterproofing performance they provide. Grace Vycor Self-Adhered Flashings are comprised of a high-density, polyethylene carrier film and a pressure-sensitive adhesive layer, both of which have unique performance advantages.
How to Apply Grace Vycor Self-Adhered Flashing Tapes PRE-INSTALLATION NOTES • ASTM E2112-01* and AAMA 2400-02* recommend the use of a minimum 9 inch wide flashing membrane beyond the rough opening. • Grace recommends a 12 inch wide flashing membrane for proper waterproofing of the window sill, providing a drainage plane in the rough opening. • Remove any weather-resistive barrier from sill area prior to membrane installation for full adhesion of the membrane to the structural sill.
Flashing Application Instructions for Windows WINDOW INSTALLATION METHOD A: BEFORE WEATHER-RESISTIVE BARRIER Based on the climatic conditions and the exposure of the window, there are a number of different flashing options. The method below is only one of the recommended options (see Detail VCRDET-102) which meets AAMA criteria. Refer to the subsequent details (VCRDET-100 to 106) for additional flashing options located on pages 27-33.
Flashing Application Instructions for Windows WINDOW INSTALLATION: METHOD A BEFORE WEATHER-RESISTIVE BARRIER (continued) 4 Step Four: Apply the pre-cut jamb flashing onto the nailing flange. Position above the head flange. Unroll flashing and expose adhesive by removing the release paper. Roll firmly into place as necessary. Repeat on the other side. 11 5 Step Five: 6 Step Six: Install the pre-cut flashing over window head flange by removing release paper. Roll firmly into place.
Flashing Application Instructions for Windows WINDOW INSTALLATION METHOD B: AFTER WEATHER-RESISTIVE BARRIER In this option (see Detail VCRDET-100) the weather-resistive barrier has already been installed before the window and flashing. 1 Step One: Cut and remove weatherresistive barrier from rough opening of window sill. Secure, if necessary, to face of sill. Score and fold weatherresistive barrier above header. Temporarily secure to allow for flashing installation.
Flashing Application Instructions for Windows WINDOW INSTALLATION: METHOD B AFTER WEATHER-RESISTIVE BARRIER (continued) 4 Step Four: Reroll the pre-cut flashing. Position inside of rough opening on the vertical jamb. Apply flashing to window sill by removing half of the release paper and exposing the adhesive. Roll firmly into position. 15 Make vertical relief cuts starting from corner of window sill upward. Roll firmly into place as necessary.
Flashing Application Instructions for Windows WINDOW INSTALLATION: METHOD B AFTER WEATHER-RESISTIVE BARRIER (continued) 6 Step Six: Install pre-cut flashing over the window head flange by removing release paper, exposing the adhesive. Roll firmly into place. Mechanically fasten head flashing at top outermost corners, as necessary. 7 Step Seven: Remove temporary securement of weather-resistive barrier above header. Fold over head flashing. Seal with weather-resistive barrier seam tape.
Flashing Application Instructions for Doors DOOR INSTALLATION Like flashing windows, Grace Vycor Plus is also the product of choice for flashing around doors. 1 Step One: Using the measurement markings, pre-cut a 12 inch piece of Grace Vycor Plus. 2 Step Two: 3 Step Three: Install onto ledger board. Install the weatherresistive barrier as per manufacturer’s recommendation. Cut out the weather-resistive barrier from rough door opening. Remove also from inside bottom of sill.
Precautions and Limitations PRECAUTIONS AND LIMITATIONS Grace Vycor Self-Adhered Flashings are designed for critical non-roof flashing details. DO NOT install on the roof. Grace Vycor Plus and Grace Vycor V40 are slippery – DO NOT walk on their surface. The surface of Grace Vycor Deck Protector, although treated with a skid-resistant coating, could also be slippery. Use special care and take all necessary fall protection precautions when walking on the membrane.
Tips from the Pros... you’ll save time and money WHAT THE PROS SAY John Kurowski, Owner Kurowski Development “When it comes to installing flashing tapes around windows and doors, it is important to use quality materials installed properly. Grace’s instructional CD clearly supports the old saying ‘a picture is worth a thousand words.’ That kind of field support helps me instruct our trade contractors better, and helps me be a better builder.
Tips from the Pros... you’ll save time and money WHAT THE PROS SAY Joe Lstiburek, Ph.D, P. Eng. Principal, Building Science Corp. “Mold problems cannot exist without water problems. No water problems, no mold problems. The sooner the water is directed out of the building structure, the better. The best expression of this concept is a flashing. Flashings are the most underrated building enclosure component and arguably the most important.
27 Flanged Window FLANGED WINDOW VCRDET-100 ® 2. Install Grace Vycor Plus head flashing under weather-resistive barrier 3. Fold weather-resistive barrier back over head flashing and seal with tape Notes: 1. For the most current details, installation video and product information, see our web site at www.graceconstruction.com ® 2.
29 Flanged Window FLANGED WINDOW – AAMA RECOMMENDATION VCRDET-102 Option 2 - AAMA Recommendation Notes: 1. For the most current details, installation video and product information, see our web site at www.graceconstruction.com ® 2. RIPCORD (Split Release on Demand) can be ® removed from Grace Vycor Plus for ease of installation 3. Install Grace Vycor Plus in order shown by numbers 4. If applicable, leave release paper on lower half of sill flashing until future tie-in 5.
31 Half Round Window HALF ROUND WINDOW – LOW TO MODERATE EXPOSURE VCRDET-104 Option 1 - Low to Moderate Exposure Notes: 1. For the most current details, installation video and product information, see our web site at www.graceconstruction.com ® 2. RIPCORD (Split Release on Demand) can be ® removed from Grace Vycor Plus for ease of installation 3. Install Grace Vycor Plus in order as shown by numbers 4. Mechanically fasten as necessary 5.
33 Sill Plate Options SILL PLATE OPTIONS VCRDET-106 Notes: 1. For the most current details, installation video and product information, see our web site at www.graceconstruction.com ® 2. RIPCORD (Split Release on Demand) can ® be removed from Grace Vycor Plus for ease of installation 3. Remove weather-resistive barrier from top of window sill plate 4. Install sill flashing as shown at left 5. Install Grace Vycor Plus around remaining window unit per Grace Window Details (VCRDET-100 to 105) 6.
35 EXTERIOR DOOR WITH DECK Exterior Sliding Door with Deck Flashing Installation After Weather-Resistive Barrier VCRDET-200 Tie-in With Weather-Resistive Barrier: 1. Integrate installation of weather-resistive barrier ® with Grace Vycor Plus to form water-shedding laps ® 2. RIPCORD (Split Release on Demand) has been removed at sill for ease of installation and/or coordnation of other trades 3. Score and fold weather-resistive barrier above header to allow for Grace Vycor Plus installation 4.
37 Joist Hanger JOIST HANGER VCRDET-300 Notes: 1. For the most current details, installation video and product information, see our web site at www.graceconstruction.com ® 2. RIPCORD (Split Release on Demand) can ® be removed from Grace Vycor Plus for ease of installation 3. Install Grace Vycor Plus and weather-resistive barrier to form water-shedding laps 4. Ensure that the Grace Vycor Flashings are not permanently exposed to UV 5.
39 Column/Post Base COLUMN/POST BASE VCRDET-302 Notes: 1. Visit www.graceconstruction.com for the most current details, installation video and product literature for furthere information ® 2. Apply Grace Vycor Deck Protector onto pressure treated wood wherever galvanized connectors would come into contact with pressure treated wood 3. Fasten galvanized connector per manufacturer guidelines and use appropriate hot-dipped galvanized fasteners per ASTM A153 4.
41 STUCCO WINDOW HEAD Stucco Window Head VCRDET-400 Notes: 1. For the most current details, installation video and product information, see our web site at www.graceconstruction.com ® 2. RIPCORD (Split Release on Demand) can be ® removed from Grace Vycor Plus for ease of installation. 3. Grace Vycor Plus can be substituted for building paper 4. Install Grace Vycor Plus and weather-resistive barrier to form water-shedding laps 5.
43 Stucco Parapet Wall STUCCO PARAPET WALL VCRDET-402 Notes: 1. For the most current details, installation video and product information, see our web site at www.graceconstruction.com ® 2. RIPCORD (Split Release on Demand) can be ® removed from Grace Vycor Plus for ease of installation 3. Grace Vycor Plus can be substituted for building paper 4. Install Grace Vycor Plus and weather-resistive barrier to form water-shedding laps 5.
45 Outside Corner OUTSIDE CORNER VCRDET-500 Notes: 1. For the most current details, installation video and product information, see our web site at www.graceconstruction.com ® 2. RIPCORD (Split Release on Demand) can be ® removed from Grace Vycor Plus for ease of installation 3. Install Grace Vycor Plus in order as shown by numbers 4. Mechanically fasten as necessary 5. Install Grace Vycor Plus and weather-resistive barrier to form water-shedding laps 6.
47 Inside Corner INSIDE CORNER VCRDET-502 Notes: 1. For the most current details, installation video and product information, see our web site at www.graceconstruction.com ® 2. RIPCORD (Split Release on Demand) can be ® removed from Grace Vycor Plus for ease of installation 3. Use a square piece of membrane (3 inches x 3 inches minimum) for inside corner 4. Use RIPCORD (Split Release on Demand) for ease of installation and to minimize scoring release paper 5. Fold as shown by arrows 6.
VCRDET-504 Notes: 1. For the most current details, installation video and product information, see our web site at www.graceconstruction.com ® 2. RIPCORD (Split Release on Demand) can be removed from ® Grace Vycor Plus for ease of installation 3. Remove release paper at time of installation of corner patch 4. Nominal patch size is 3 inches x 3 inches 5.
51 Foundation Sill Plate FOUNDATION SILL PLATE – OPTION 1 VCRDET-505 Option 1 Notes: 1. For the most current details, installation video and product information, see our web site at www.graceconstruction.com ® 2. RIPCORD (Split Release on Demand) can ® be removed from Grace Vycor Plus for ease of installation 3. Install Grace Vycor Plus in order shown by numbers 4. Install Grace Vycor Plus and weather-resistive barrier to form water-shedding laps ® 5.
CHEMICAL COMPATIBILITY Frequently during the design of an assembly, the designer will question the chemical compatibility of self-adhered flexible flashings with other materials. ® Grace Vycor Self-Adhered Flashings (Grace Vycor Plus, Grace Vycor V40 and Grace Vycor Deck Protector) are chemically compatible with most substances and products that are normally present in common application environments. Grace Vycor Self-Adhered Flashings are compatible with acids, bases, and salts.
EXPOSURE GUIDELINES Technical Letter 3 Exposure Guidelines Cold Temperature Applications ® Grace Vycor Self-Adhered Flashings (Grace Vycor Plus, Grace Vycor V40 and Grace Vycor Deck Protector) are not intended to be left permanently exposed to direct sunlight. Flashings should be covered and protected from sunlight as soon as possible. Grace Vycor Self-Adhered Flashings may be left exposed up to 30 days if necessary, to accommodate construction scheduling or weather problems.
SURFACE PREPARATION Technical Letter 5 Surface Preparation Shelf Life ® Grace Vycor Self-Adhered Flashings (Grace Vycor Plus, Grace Vycor V40 and Grace Vycor Deck Protector) are to be applied directly to a clean and dry surface. Some suitable substrates include wood, pressure-treated wood, plywood, wood composition, oriented strand board (OSB), metal, vinyl, concrete, masonry and gypsum sheathing.
End of WINDOW, DOORS AND DETAIL AREAS Flip book for Decks and Detail Areas installation