Full Product Manual
CFR), Fall Protection Systems Criteria and Practices
– 1926.502.
10.Check local building code to ensure compliance in
your area, as local building codes may vary.
Code Approvals
• Complies with AC-188 Acceptance Criteria for Roof
Underlayments
ICC ESR-3509.
• Meets the requirements of Florida Building Code,
Approval #FL16038.1-R0
• Complies with ASTM E108/UL 790 for use in
the installation of Class A asphalt glass ber mat
shingles and Class C asphalt organic felt or metal
shingles
• Meets ASTM D226 physical requirements of Type I
and Type II (No. 15 asphalt felt)
Precautions and Limitations
• Consistent with good roong practice, always wear
fall protection when working on a roof deck.
• Slippery when wet or covered by frost, debris or
dust.
• Do not fold over the roof edge unless the edge is
protected by a drip edge, gutter or other ashing
material.
• Check with the manufacturer of the metal roong
system for any special requirements when used under
metal roong. Do not install directly under roof
coverings especially sensitive to corrosion, such as
zinc, without providing proper ventilation.
Performance Properties
Property Grace SYN 15™ Test Method
Color Black
Weight 20 lbs (10 sq roll)
Tear strength MD 36 lbs; CD 36 lbs ASTM D4533
Accelerated aging Pass (no damage, cracking, chipping) ICC-ES AC48
Ultraviolet resistance Pass (no peeling, chipping, cracking, aking) ICC-ES AC48
Water ponding Pass (no percolation) ASTM D779
Pliability Pass (no cracks) ASTM D226
Water transmission Pass ASTM D4869
Tensile strength MD 66 lbs; CD 49 lbs ASTM D828
Thickness 7 mils ASTM D3767
Product Data
10 sq Roll
Roll length 250 ft (76.2 m)
Roll width 48 in (1.05 m)
Roll size 1,000 ft
2
(92.9 m
2
)
Roll weight 20 lbs (9.1 kg)
Rolls per pallet 35
57