GCL Installation Guide
MECHANICAL INSTALLATION
Location Selection
Installation Angle
Local Latitude
0°~ 15° 15°
Latitude
Latitude
+5°
Latitude+10°
Latitude+15°
Latitude+20°
15°~ 25°
25°~ 30°
30°~ 35°
35°~ 40°
>40°
Module installation angle
Table 1
GCL System Integration Technology Co.,Ltd
Bringing Green Power to Life
04
Select suitable places to install Modules.
Install Modules at the places with sucient sunlight and without shade at any time. If
a module is shaded or even partially shaded, it will result in lower power output. A
permanent or regular shade will cause damage to the module, which will void GCLSI’s
warranty.
Do not place, install or use Modules at the places where combustible gas is easily
generated or gathering.
The straight-line distance between the installation site and coastline shall not be
shorter than 1 km unless there is a written approval from GCLSI or an engagement
specied in the contract.
Modules in the same string should be installed at the same angle. Modules installed in
dierent angles will receive dierent irradiation, which will cause current dierent. As
a result, it will decrease the operation eciency of the system.
Please refer to Table 1 for the recommended installation angles of the Modules.