9. Ignition Unit
(Slide Control Model only)
9.1 Remove the battery, see Section 2.
9.2 Remove the 2 leads and the pilot ignition lead from the
ignition unit, see Diagram 36.
Leads
36
Pilot Ignition
Lead
Screw
Screw
(Behind unit)
9.3 Undo the 2 screws securing the unit in place, see
Diagram 33.
9.4 Replace in reverse order.
10. Changing between Gas Types
The following parts must be changed when converting an
appliance from one gas type to another:
Manual Control:
BURNER ASSEMBLY DATABADGE
NG LPG NG LPG
LOGIC HE -
COAL
GZ8187 GZ8335 PR1053 PR1059
LOGIC HE -
STONE
GZ8152 GZ8333 PR1060 PR1061
Remote Control:
BURNER ASSEMBLY DATABADGE
NG LPG NG LPG
LOGIC HE -
COAL
GZ10733 GZ11165
PR1878
LOGIC HE -
STONE
GZ11168 GZ11169
Slide Control:
BURNER ASSEMBLY DATABADGE
NG LPG NG LPG
LOGIC HE -
COAL
GZ9476 GZ11113
PR1591
LOGIC HE -
STONE
GZ11116 GZ11124
Note: The control valve will be set for the particular
appliance and gas type. In all instances, when ordering
new parts, be sure to quote the appliance type and serial
number.
Use only genuine Gazco replacement parts.
Non-standard components will invalidate the guarantee
and may be dangerous.