Balanced Flue Instructions
38
Servicing Instructions - Replacing Parts
VERMICULITE LINER
4.26 The rear liner does not need to be removed in order to
access the burner tray for maintenance, however it is
advisable to remove the rear panel to avoid possible
damage and to clean or replace.
4.27 To remove the back panel lift out of the bracket and remove
through the front of the appliance, see Diagram 17.
17
4.28 With the liners and baffle removed the firebox is clear for
cleaning and maintenance, see Diagram 18.
18
5. Main Burner
5.1 To replace the main burner:
Remove the baffle and enamel liners, see Section 4.
5.2 Remove the three securing screws from the edges of the
burner, see Diagram 19.
19
Screws
Midi Version Shown
5.3 Slide the burner fully to the right whilst lifting the Left Hand
side clear of the bracket, see Diagram 20.
20
Slide to the right and
lift the Left hand side
Midi Version Shown
5.4 Slide the burner back to the left and out of its location.
IMPORTANT: Take care when removing the burner not to
damage the ceramic pad with the pilot unit attached.
Refit in reverse order
6. Control Assembly
6.1 It is not necessary to remove the complete control assembly
to service or replace parts of this appliance. The following
sections will detail how to individually remove and replace
each element.
7. Pilot Unit
7a. Small & Midi
The pilot assembly consists of 4 components, which can be
individually changed, these are:
Pilot burner bracket.
Pilot Injector
Electode
Thermocouple.
Gasket.
7.1 Turn the gas supply off at the isolation device, remove the
door and place to one side, carefully remove the ceramic fuel
bed components.
Pilot Burner Bracket
7.2 Remove the two fixing screws from the pilot bracket, see
Diagram 21. Gently draw the assemble away from the
firebox to give access to the nuts and ignition lead.
NOTE: TAKE CARE NOT TO DAMAGE THE GASKET.
21
Nat Gas
Vision Midi
only
LPG