MINIMUM CLEARANCE
7.8 The appliance is not suitable for installation against a
combustible wall. All combustible materials must be
removed from behind the appliance.
7.9 Ensure that all minimum clearances to combustible
materials are complied with, see Diagrams 9 & 10.
The specified clearances provide the minimum distance to
combustible materials. If the appliance is intended to be
installed into a non-combustible opening the clearance to the
sides and above the appliance can be reduced. However, it
is recommended that the specified clearances are
maintained irrespective of the materials used in the
construction of the opening to allow adequate air flow and
access to controls. The clearance at the rear of the
appliance must always be a minimum of 50mm.
150
225
150
9
50mm
150mm
10