Balanced Flue Instructions
18
Installation Instructions
Site Requirements
5. Gas Supply
THIS APPLIANCE IS INTENDED FOR USE ON A GAS
INSTALLATION WITH A GOVERNED METER.
5.1 Before installation, ensure that the local distribution
conditions (identification of the type of gas and pressure)
and the adjustment of the appliance are compatible.
5.2 Ensure the gas supply delivers the required amount of gas
and is in accordance with the rules in force.
5.3 You can use soft copper tubing on the installation and soft
soldered joints outside the appliance and below the fire.
5.4 A factory fitted isolation device is part of the inlet connection;
no further isolation device is required.
5.5 All supply gas pipes must be purged of any debris that may
have entered prior to connection to the appliance.
5.6 The gas supply enters through the rear of the LEFT-HAND
side of the outer box:
5.7 The gas supply must be installed in a way that does not
restrict the removal of the appliance for servicing and
inspection.
6. Ventilation
6.1 This appliance requires no additional ventilation.
7. Appliance Location
7.1 This appliance has been designed to stand on either a
hearth or an optional bench:
RVACLB100B - Riva Bench Low (100cm wide)
RVACB100B - Riva Bench (100cm wide)
RVACLB120B - Riva Bench Low (120cm wide)
RVACB120B - Riva Bench (120cm wide)
RVACLB140B - Riva Bench Low (140cm wide)
RVACB140B - Riva Bench (140cm wide)
7.2 To Install the Bench:
Follow Section 1 Installation - All Models in Installation guide
PM205 supplied with the bench kit.
7.3 To secure the appliance to the bench:
You must consider where you place the appliance on the
bench before drilling the bench, see Diagram 7.
7
Once the position of the appliance has been decided:
Follow the instructions for securing the appliance on Page 20.
7.4 The non-combustible hearth must be at least 12mm thick,
and project a minimum of 50mm from the base of the
appliance in all directions.
7.5 The appliance is not suitable for installation against a
combustible wall. A combustible side wall must be a
minimum of 150mm from the appliance.
7.6 This appliance can be installed with an up and out flue
(vertical wall - horizontal flue) or with a vertical flue with roof
termination (see Flue Options, Section 2 Site
Requirements).
HEARTH INSTALLATION
7.7 Building Regulations state this appliance must stand on a
non-combustible hearth that is at least 12mm thick and
projects 50mm minimum from the base of the appliance in
all directions, however Gazco recommend the hearth
extends to the following dimensions, see Diagram 8.
C
A
B
8
Dimensions Small Midi Medium
A 670mm 715mm 835mm
B 389mm 411mm 453mm
C 12mm 12mm 12mm