Logic HE Conventional Flue Combined Controls Installation User Instructions

5
User Instructions
Adjusting the Flame height
2.5 From the pilot position push the valve knob in slightly and
rotate anti-clockwise until the first stop point is felt.
This denotes the lowest setting.
2.6 Push the valve knob in slightly and rotate further in an anti-
clockwise direction.
The final stop point is the highest setting.
Pilot
position
Low Setting
High Setting
Off position
2
IMPORTANT: YELLOW FLAMES TYPICALLY
APPEAR WHEN THE APPLIANCE HAS REACHED
NORMAL OPERATING TEMPERATURE. THIS CAN
TAKE UP TO 30 MINUTES.
WARNING: IF THE APPLIANCE FAILS TO LIGHT
OR BECOMES EXTINGUISHED IN USE, WAIT 3
MINUTES BEFORE ATTEMPTING TO RELIGHT.
Switching OFF the Appliance
2.7 To switch the appliance off turn the control knob clockwise
until it is returned to the off position, see Diagram 3.
3
Rotate clockwise
The knob should be upright.
Remote Control
The control valve is at the foot on the right-hand side of the
appliance. It has two controls, see Diagram 4:
1. The right-hand knob controls the pilot ignition
2. The left-hand knob controls the main burner
Lighting the Pilot
2.8 To start the left-hand and right-hand control knobs must
both point to off ( ):
4
2.9 Press in the right-hand control knob and rotate anti-
clockwise until a click is heard. Continue to press in. The
knob points to the pilot ( ).
The pilot is lit.
2.10 Keep the knob depressed for 10 seconds before releasing.
The pilot remains lit.
Repeat the above steps if the pilot does not stay lit.
NOTE: If the pilot goes out, the Interlock system
prevents you lighting again for a short period.
2.11 If, after repeating the above steps the pilot does not light,
contact your Retailer or Installer.
2.12 Turn the right-hand control to point to main burner ( ).
The appliance can now be controlled by the remote
handset.
2.13 The Standard remote controls the appliance when:
— the pilot is lit.
— the right-hand control points to main burner ready to
operate position.
It regulates the temperature from low to high and back.
It can also turn the main burner off leaving just the pilot
burning and ready to operate.
A
B
C
5