Logic HE Conventional Flue Combined Controls Installation User Instructions

13
Installation Instructions
Technical Specification - Coal Effect
Covering the following models:
Model
Gas
Cat.
Gas Type
Working
Pressure
Aeration Injector
Gas Rate
m
3
/hr
Input kW
(Gross)
Country
High Low High Low
Logic HE
Manual
I
2H
Natural G20 20mb 5 x 16 063 0.486 0.238 5.1 2.5 GB, IERemote
Slide
Logic HE
Manual
I
3P
Propane G31 37mb
(1) 10 x 16
(1) 23 x 15
150
0.181 0.090 4.8 2.4
GB, IE
Remote 0.181 0.090 4.8 2.4
Slide 0.184 0.090 4.9 2.4
Efciency 89% Net (Class 1)
No
x
Class 3
Min Flue Size - 5" diameter
Min Flue Size - pre cast - 90mm x 183mm (16,500mm
2
)
Min Flue Specication - T250/N2/0/D/1
Gas Inlet - 8mm
Gas
Type
Logic HE Coal Effect
Manual Control Remote Control Slide Control
Nat Gas 101-151 101-088 101-037
LpG 101-497 101-614 101-444
The net efficiency of this appliance has been measured as specified in BS7977-1:2009 and the result after conversion to
gross using the appropriate factor from Table E4 of SAP 2012 is 80.2%. The test data has been certified by BSI Testing
Services. The gross efficiency value may be used in the UK Government's Standard Assessment Procedure (SAP) for
energy rating of dwellings.