Logic HE Conventional Flue Combined Controls Installation User Instructions

12
Installation Instructions
Technical Specification - Stone Effect
Covering the following models:
Gas
Type
Logic HE Stone Effect
Manual Control Remote Control Slide Control
Nat Gas 101-324 101-131 101-110
LpG 101-651 101-649 101-597
Model
Gas
Cat.
Gas Type
Working
Pressure
Aeration Injector
Gas Rate
m
3
/hr
Input kW
(Gross)
Country
High Low High Low
Logic HE
Manual
I
2H
Natural G20 20mb 6mm x 6mm 240 0.390 0.238 4.1 2.5 GB, IERemote
Slide
Logic HE
Manual
I
3P
Propane G31 37mb 12mm x 15mm 102 0.162 0.090 4.3 2.4 GB, IERemote
Slide
Efciency 89% Net (Class 1)
No
x
Class 4
Min Flue Size - 5" diameter
Min Flue Size - pre cast - 90mm x 183mm (16,500mm
2
)
Min Flue Specication - T250/N2/0/D/1
Gas Inlet - 8mm
The net efficiency of this appliance has been measured as specified in BS7977-1:2009 and the result after conversion to
gross using the appropriate factor from Table E4 of SAP 2012 is 80.2%. The test data has been certified by BSI Testing
Services. The gross efficiency value may be used in the UK Government's Standard Assessment Procedure (SAP) for
energy rating of dwellings.