Logic HE Balanced Flue Log Installation User Instructions
13
8. Flame Failure Device
8.1 This is a safety feature incorporated on this appliance which
automatically switches off the gas supply if the pilot goes out
and fails to heat the thermocouple.
Remote Only: In the event of flame extinction the control
will make several attempts to restart. DO NOT interrupt the
valve during this process.
IF THIS OCCURS DO NOT ATTEMPT TO RELIGHT THE
APPLIANCE FOR 3 MINUTES.
9. Running In
9.1 During initial use of a new GAZCO appliance a strong odour
will be encountered as various surface coatings become hot
for the first time. Although these odours are harmless it is
recommended that the appliance is operated on maximum
for 4 to 8 hours in order to fully burn off these coatings. After
this period the odours should then disappear.
If the odours persists, please contact your installer for
advice.
9.2 During the first few hours of burning there may be
discolouration of the flames. This will also disappear after a
short period of use.
10. Servicing
10.1 The appliance must be serviced every 12 months by a
qualified GasSafe Engineer. In all correspondence always
quote the Model number and the Serial number which may
be found on the Commissioning Checklist (Page 3).
11. Ventilation
11.1 This appliance requires no additional ventilation.
12. Installation Details
12.1 Your installer should have completed the commissioning
sheet at the front of this book. This records the essential
installation details of the appliance. In all correspondence
always quote the Model number and Serial number.
13. Hot Surfaces
13.1 Parts of this appliance become hot during normal use.
13.2 Regard all parts of the appliance as a working surface,
except for the control access panel and the slider handle
(slide control model only).
13.3 Provide a suitable fire guard to protect young children and
the infirm.
User Instructions