Remote Control
The pilot on Remote Control appliances must be lit
manually from the valve unit before operation.
The control valve is at the foot on the right-hand side of the
appliance. It has two controls, see Diagram 34:
1. The right-hand knob controls the pilot ignition.
2. The left-hand knob controls the main burner.
Lighting the Pilot
10.8 To start the left-hand and right-hand control knobs must
both point to off ( ):
34
10.9 Press in the right-hand control knob and rotate anti-
clockwise until a click is heard. Continue to press in. The
knob points to the pilot ( ).
The pilot is lit.
10.10 Keep the knob depressed for 10 seconds before releasing.
The pilot remains lit.
Repeat the above steps if the pilot does not stay lit.
NOTE: If the pilot goes out, the Interlock system
prevents you lighting again for a short period.
10.11 If, after repeating the above steps the pilot does not light,
contact your Retailer or Installer.
10.12 Turn the right-hand control to point to main burner ( ).
The appliance can now be controlled by the remote
handset.
10.13 The Standard remote controls the appliance when:
— the pilot is lit.
— the right-hand control points to main burner ready to
operate position.
It regulates the temperature from low to high and back.
It can also turn the main burner off leaving just the pilot
burning and ready to operate.
A
B
C
35
Installation Instructions
To light the main burner:
10.14 Press buttons A & B simultaneously.
The remote’s LED light flashes to show communication
between the appliance's controls and the remote.
Adjusting the Flame height:
10.15 Press and hold buttons A & B simultaneously to increase
the flame height. A clicking sound indicates that the
appliance is at maximum.
10.16 Press and hold button C to decrease the flame height.
Continue to press C to turn off the main burner.
To make small adjustments to flame height:
10.17 Press and hold down button B and press button A once to
make a slight increase. This increases the temperature by
stages.
Repeat to further adjust.
10.18 Press button C once to slightly reduce the flame height.
IMPORTANT: YELLOW FLAMES TYPICALLY
APPEAR WHEN THE APPLIANCE HAS REACHED
NORMAL OPERATING TEMPERATURE. THIS CAN
TAKE UP TO 30 MINUTES.
WARNING: IF THE APPLIANCE FAILS TO LIGHT OR
BECOMES EXTINGUISHED IN USE, WAIT 3
MINUTES BEFORE ATTEMPTING TO RELIGHT.
Switching OFF the Appliance
THE REMOTE CONTROL CAN TURN THE MAIN
BURNER OFF AND LEAVE THE PILOT BURNING AND
READY TO OPERATE .
10.19 To switch off the appliance completely (no pilot burning)
return both control knobs to the off position ( ).
Remote Control
10.20 To turn the main burner of the appliance off using the
handset press and keep pressing the Off button ( ).
The main burner goes out leaving the pilot burning and
ready to run .
Controls on Appliance
10.21 Use the controls on the appliance to turn the appliance off
by turning the left-hand control knob until it points to Off ( ).
A click is heard and the main burner goes out leaving the
pilot burning and ready to run .
CAUTION: IN RARE INSTANCES, NOISES FROM
SOURCES OUTSIDE THE REMOTE CAN OPERATE THE
MAIN BURNER. IF THIS OCCURS, ALWAYS TURN THE
CONTROL TO PILOT ( ) OR OFF.