Installation Instructions
Technical Specification - Coal Effect
Covering the following models:
Model
Gas
Cat.
Gas Type
Working
Pressure
Aeration Injector
Gas Rate
m
3
/hr
Input kW
(Gross)
Country
High Low High Low
Logic HE
Manual
I
2H
Natural G20 20mb 8mm x 15mm 260
0.381 0.219 4.0 2.3
GB, IERemote 0.400 0.219 4.2 2.3
Slide 0.39 0.219 4.1 2.3
Logic HE
Manual
I
3P
Propane G31 37mb
23mm x
15mm (2)
104
0.150 0.083 4.0 2.2
GB, IERemote 0.154 0.083 4.1 2.2.
Slide 0.154 0.083 4.1 2.2
Efciency 86% Net (Class 1)
NOx Class 3
Flue Outlet Size Ø 100mm
Flue Inlet Size Ø 152mm
Gas Inlet Connection Size Ø 8mm
Gas
Type
Logic HE Coal Effect
Manual Control Remote Control Slide Control
Nat Gas 101-135 101-174 101-237
LpG 101-458 101-738 101-639
The net efficiency of this appliance has been measured as specified in EN613:2001 and the result after conversion to gross
using the appropriate factor from Table E4 of SAP 2012 is 77.5%. The test data has been certified by BSI Testing Services.
The gross efficiency value may be used in the UK Government's Standard Assessment Procedure (SAP) for energy rating
of dwellings.