Logic HE Balanced Flue Combined Controls Installation User Instructions
12
Installation Instructions
Technical Specification - Stone Effect
Covering the following models:
Gas
Type
Logic HE Stone Effect
Manual Control Remote Control Slide Control
Nat Gas 101-208 101-182 101-386
LpG 101-687 101-777 101-753
Model
Gas
Cat.
Gas Type
Working
Pressure
Aeration Injector
Gas Rate
m
3
/hr
Input kW
(Gross)
Country
High Low High Low
Logic HE
Manual
I
2H
Natural G20 20mb 6mm x 10mm 200 0.324 0.2 3.4 2.1 GB, IERemote
Slide
Logic HE
Manual
I
3P
Propane G31 37mb 12mm x 15mm 95 0.128 0.079 3.4 2.1 GB, IERemote
Slide
Efciency 86% Net (Class 1)
NOx Class 4
Flue Outlet Size Ø 100mm
Flue Inlet Size Ø 152mm
Gas Inlet Connection Size Ø 8mm
The net efficiency of this appliance has been measured as specified in EN613:2001 and the result after conversion to gross
using the appropriate factor from Table E4 of SAP 2012 is 77.5%. The test data has been certified by BSI Testing Services.
The gross efficiency value may be used in the UK Government's Standard Assessment Procedure (SAP) for energy rating
of dwellings.