Riva2 Gas Fires Brochure
The above information is to assist you in your choice of a suitable Gazco fire. This is not intended to be all the information required to install your fire. This can be obtained from your local Gazco retailer or you can download the full installation instructions from the Gazco website at www.gazco.com
RIVA2 500HL SLIMLINE DIMENSIONS (mm)
RIVA2 500HL TYPICAL INSTALLATION FOR ESPRIT
WALL (FIXING) BRACKET TO
POSITION APPLIANCE TO
SECURE & POSITION APPLIANCE.
58,3
76,2 (3")
10 (MIN)
77
60
671,75
RIVA2 500HL TYPICAL INSTALLATION FOR ESPRIT
WALL (FIXING) BRACKET TO
POSITION APPLIANCE TO
SECURE & POSITION APPLIANCE.
58,3
76,2 (3")
10 (MIN)
77
60
671,75
TYPICAL INSTALLATION FOR ESPRIT SURROUND
RIVA2 500HL TYPICAL INSTALLATION FOR 75mm (3") REBATED MANTEL & SLIP
BUILD ONTO EXISTING WALL (ALLOWING FOR 76mm/3" OFFSET
ENSURING THAT FINISHED SURFACE ALIGNS TO PRODUCT FLANGES.
RIVA2 500HL TYPICAL INSTALLATION FOR EDGE/VERVE XS/ICON XS
DISTANCES TO NON-COMBUSTIBLES MUST BE MAINTAINED.
MANTEL/
SURROUND
SLIP
59,2
76,2
TYPICAL INSTALLATION FOR EDGE, VERVE XS & ICON XS
Description Frame Finish
Product Code
Frame Size (mm)
w h d
Verve XS Graphite
934-229
890 755
57
Icon XS Black Glass
934-247
855 828
27
Esprit Graphite
934-268
746 1211 125
RIVA2 500HL SLIMLINE FRAME INFORMATION
Product Code Description
934-289
Riva2 500 HL Slimline Balanced Flue Black Reeded Lining Set
934-294
Riva2 500 HL Slimline Balanced Flue Vermiculite Lining Set
934-306
Riva2 500 HL Slimline Balanced Flue Black Glass Effect Lining Set
999-620
Remote System Mains Adaptor
RIVA2 500HL SLIMLINE OPTIONS
When installed into the inner leaf of a cavity wall, the front face of the appliance will require
a 75mm (3”) rebated surround complete with a finishing slip to house the remaining
appliance depth. Alternatively, a slim studwork chimney breast could be constructed and
the appliance can then either be finished as an “Edge” installation or finished with either the
Verve XS or Icon fronts. The appliance is also suitable for installation into a cavity wall in
conjunction with the Esprit front which will house the remaining depth.
RIVA2 500HL SLIMLINE ESPRIT SURROUND
500
520,5 (INT-INT.)
705
546
109
17
230
330
RIVA2 500HL BF
PROVISIONAL PRODUCT DIMENSIONS - MAY 2017
549 ±1
EDGE
629
522,3 ±1
EDGE
553
212
553
549
17
230
330
500
520,5 (INT-INT.)
705
546
109
17
230
330
RIVA2 500HL BF
PROVISIONAL PRODUCT DIMENSIONS - MAY 2017
549 ±1
EDGE
629
522,3 ±1
EDGE
553
212
500
629
705
520
500
520,5 (INT-INT.)
705
546
109
17
230
330
RIVA2 500HL BF
PROVISIONAL PRODUCT DIMENSIONS - MAY 2017
549 ±1
EDGE
629
522,3 ±1
EDGE
553
212
212
546
109
522
Riva2 500HL Slimline
134-126
Balanced Nat. Gas 6.00kW 4.60kW B 86% Prog. Thermostatic Vermiculite 565 695 240
134-499
Balanced LPG 4.90kW 3.80kW C 84% Prog. Thermostatic Vermiculite 565 695 240
134-115
Balanced Nat Gas 6.00kW 4.60kW B 86% Prog. Thermostatic Black Reeded 565 695 240
134-481
Balanced LPG 4.90kW 3.80kW C 84% Prog. Thermostatic Black Reeded 565 695 240
134-102
Balanced Nat. Gas 6.00kW 4.60kW B 86% Prog. Thermostatic Black Glass 565 695 240
134-478
Balanced LPG 4.90kW 3.80kW C 84% Prog. Thermostatic Black Glass 565 695 240
Product
Code
Flue
Type
Gas
Type
Heat
Input
Heat
Output
Energy
Efficiency
Class
Efficiency
Remote
Control
Lining
w h d
RIVA2 500HL SLIMLINE FIRE INFORMATION
X
X
X
X
X
X
Opening Size (mm)
549
521
460 *230 *
746
77
125
1211
549
521
460 *230 *
746
77
125
1211
1211
521
549
230 230
125746
77
REAR EXIT BALANCED FLUE TERMINATION KIT
The Riva2 500HL Slimline comes complete with a specific
rear exit balanced flue termination kit (8526) included.
395 x 200 x 200 mm (H x W x D) Guard supplied.
Cut to length as required on site.
64