IMPORTANT: YELLOW FLAMES TYPICALLY
APPEAR WHEN THE APPLIANCE HAS REACHED
NORMAL OPERATING TEMPERATURE. THIS CAN
TAKE UP TO 30 MINUTES.
WARNING: IF THE APPLIANCE FAILS TO LIGHT OR
BECOMES EXTINGUISHED IN USE, WAIT 3
MINUTES BEFORE ATTEMPTING TO RELIGHT.
2.2 There are 3 different modes available for controlling and
operating the appliance:
1. Manual Mode
2. Temp Mode (Automatic)
3. Timer Mode (Automatic)
2.3 In MANUAL MODE you can:
— turn on the main burner using the UP button
— regulate the flame from high to low and back
— turn off the burner leaving just the pilot burning
In TEMP MODE (Automatic) you can:
— set the room temperature so the thermostat in the remote
automatically maintains that temperature
In TIMER MODE (Automatic) the appliance:
— turns on and off according to the set time periods
— automatically regulates the room temperature during the
set periods
NOTE: When operating the appliance in Temp or Timer
mode, the pilot remains lit and the appliance then
automatically switches on at programmed times to bring
the room to the set temperature whether or not you are in
the room.
NEVER LEAVE ANY COMBUSTIBLE MATERIALS WITHIN
1 METRE OF THE FRONT OF THE APPLIANCE.
Switching Between Modes
2.4 Press the SET button to change to Temperature Mode.
Press again to change to Timer Mode.
Keep pressing to run through all operating modes. These
are:
— MAN
— DAY TEMP
— NIGHT TEMP
— TIMER
and back to MAN
NOTE: MAN mode can also be reached by pressing
either the UP or DOWN button.
Manual Mode
2.5 Press the OFF button and the UP button simultaneously.
You hear several clicks and audible beeps as the appliance
begins the ignition process, (up to 30 seconds).
Turning the appliance Off:
Press the OFF button to turn the appliance off.
FOR SAFETY, YOU MUST WAIT 30 SECONDS BEFORE
LIGHTING THE APPLIANCE AGAIN.
Increasing the Flame Height:
Press the UP button once to increase flame height one stage.
Press and hold the UP button to increase to maximum.
Decreasing the Flame Height:
Press the DOWN button once to decrease flame height
one stage. Press and hold the DOWN button to decrease to
minimum. At the lowest point the appliance goes to 'Standby
Mode' (Only Pilot lit).
NOTE: While pressing a button a symbol indicating
transmission appears on the display. The receiver
confirms transmission with a sound signal.
Temp Mode (Automatic)
2.6 The display shows the current room temperature.
To increase or decrease the appliance’s output:
Press the SET button to select either the DAY TEMP
or the NIGHT TEMP mode by briefly pressing the
SET button.
Hold the SET button until the TEMP display flashes and
then let go.
Set the desired temperature with the UP and DOWN arrows.
(Minimum temperature 5C, maximum 40C or 40F to 99F
when Fahrenheit is the preferred option).
Press the OFF button to stop the display flashing or wait
to return to TEMP mode.
NOTE: If you set a temperature that is beneath the
current room temperature, the appliance automatically
switches to PILOT (Stand by).
If you would like the Night temperature control to turn
off then decrease the temperature until [--] is displayed.