Riva2 600 Balanced Flue Installation Instructions

40
IMPORTANT The cables must follow the same route
when they are replaced.
6.17 When replacing the cover plate ensure silicone sealant is
used to seal the aperture.
6.18 The cable can only be fitted on way round, ensure this is
correct when refitting a replacement.
IMPORTANT Ensure that the red end of the ignition
cable is reconnected to the electrode.
7. Ignition Lead
IMPORTANT The Ignition lead and the Thermocouple
need to be removed at the same time regardless of
which needs to be replaced.
See Section 6d.
8. Gas Valve
To change the gas valve:
8.1 Remove the Main Burner and the Main Control Assembly,
see Sections 4 and 5.
8.2 Release the gas inlet pipe, see Diagram 25, Arrow A.
B
A
C
D
25
8.3 Remove the thermocouple from the interrupter block.
8.4 Release the pilot pipe, see Diagram 25, Arrow B.
8.5 Release the gas outlet pipe, see Diagram 25 Arrow C.
8.6 Remove the eight wire loom, see Diagram 25, Arrow D.
8.7 Remove the two screws securing the valve to the support
bracket and withdraw the valve.
8.8 Replace in reverse order.
9. Magnetic Safety Valve
To replace the magnetic safety valve:
9.1 Undo the thermocouple from the interrupter block and
remove the two interrupter leads.
9.2 Unscrew the interrupter block from the back of the valve.
9.3 Undo the silver magnetic valve retaining nut on the back of
the valve.
9.4 Gently tap out the mag valve.
9.5 Replace with a new unit.
9.6 Reassemble in reverse order ensuring that the interrupter
leads are connected correctly with the blue tag lead furthest
away from the gas valve body.
10. Control Box
10.1 Remove the Main Burner and the Main Control Assembly,
see Sections 4 and 5.
10.2 Remove the two thermocurrent cables by removing the two
screws, see Diagram 26.
10.3 Remove the ignition lead, see Diagram 26.
10.4 Remove the eight wire loom from the control box.
10.5 Remove the battery extension cable, see Diagram 26.
The control box can now be replaced.
26
Pilot Burner
8 Wire Cable
Ignition Cable
Interrupter Block
Reset Button
GV60 Valve
Battery Cable/
Mains Adaptor
(Optional)
Thermocurrent
Cable SW
Thermocurrent
Cable TC
Servicing Instructions - Replacing Parts