6b. Electrode
6.5 Pull the ignition lead off the electrode and undo the retaining
nut, see Diagram 20.
20
6.6 Replace with a new electrode. Do not over-tighten the nut;
this could break the component.
6.7 Replace the ignition lead.
6c. Pilot Injector
6.8 Undo the pilot pipe from the bulkhead and from the
underside of the pilot burner, see Diagram 21.
21
Nut
Nut
6.9 Remove the pipe and the injector drops out from the burner.
6d. Thermocouple
IMPORTANT The Ignition lead and the Thermocouple
need to be removed at the same time regardless of
which needs to be replaced.
6.10 Unplug the Ignition lead from the electrode and undo the
brass nut to remove the thermocouple from the pilot burner
unit, see Diagram 18.
6.11 Undo the brass nut from the back of the interrupter block to
disconnect the thermocouple, see Diagram 22.
Nut
Interrupter Block
22
6.12 Unplug the Ignition lead from the control box, see Diagram 23.
Ignition Lead
23
6.13 Carefully cut cable ties from the vidaflex.
IMPORTANT Ensure not to cut the cables.
6.14 Remove screw and sealant from plate, see Diagram 24.
24
6.15 Feed ignition lead and thermocouple complete with vidaflex
through metal plate.
6.16 Withdraw ignition lead and thermocouple from vidaflex
sleeve. THIS MUST BE KEPT AND ASSEMBLED ON THE
NEW LEAD. A CABLE TIE MUST ALSO BE USED TO
RETAIN THE SLEEVE.
Servicing Instructions - Replacing Parts