10.7 Lower the rear panel carefully and lean the top up against
the back of the appliance.
10.8 Support the rear liner and replace the 2 brackets, see
Diagram 38.
38
10.9 To fit the Right Hand liner insert through the front of the
appliance tilting the top inwards towards the centre of the
firebox before lowering into position, see Diagram 39.
39
10.10 To t the Left Hand liner insert through the front of the
appliance tilting the top inwards towards the centre of the
rebox before lowering into position, see Diagram 39.
10.11 Replace the side liner brackets, see Diagram 40.
40
Installation Instructions
10.12 Replace the baffle ensuring that the rear locates on the shelf
at the shelf at the back of the firebox, see Diagram 41.
Take care not to damage the liners.
Screws
Shelf
41
10.13 Replace the screws to secure it to the roof of the firebox,
see Diagram 41.
Advice on handling and disposal
of fire ceramics
The fuel effect and side panels in this appliance
are made from Refractory Ceramic Fibre (RCF), a
material which is commonly used for this
application.
Protective clothing is not required when
handling these articles, but we recommend you
follow normal hygiene rules of not smoking,
eating or drinking in the work area and always
wash your hands before eating or drinking.
To ensure that the release of RCF fibres are kept
to a minimum, during installation and servicing a
HEPA filtered vacuum is recommended to
remove any dust accumulated in and around the
appliance before and after working on it. When
servicing the appliance it is recommended that
the replaced items are not broken up, but are
sealed within heavy duty polythene bags and
labelled as RCF waste.
RCF waste is classed as stable, non-reactive
hazardous waste and may be disposed of at a
licensed landfill site.
Excessive exposure to these materials may
cause temporary irritation to eyes, skin and
respiratory tract; wash hands thoroughly after