Riva2 600 Balanced Flue Installation Instructions

19
Installation Instructions
1. Safety Precautions
1.1 For your own and other’s safety, you must install this
appliance according to local and national codes of practice.
Failure to install the appliance correctly could lead to
prosecution. Read these instructions before installing
and using this appliance.
1.2 These instructions must be left intact with the user.
1.3 Do not attempt to burn rubbish on this appliance.
1.4 Keep all plastic bags away from young children.
1.5 Do not place any object on or near to the appliance and
allow adequate clearance above the appliance.
IF THE APPLIANCE IS EXTINGUISHED OR GOES OUT
IN USE, WAIT 3 MINUTES BEFORE ATTEMPTING TO
RELIGHT THE APPLIANCE.
IMPORTANT: REFER TO DATA BADGE AND
TECHNICAL SPECIFICATION AT THE FRONT OF
THE MANUAL TO ENSURE THE APPLIANCE IS
CORRECTLY ADJUSTED FOR THE GAS TYPE AND
CATEGORY APPLICABLE IN THE COUNTRY OF
USE.
FOR DETAILS OF CHANGING BETWEEN GAS
TYPES REFER TO SERVICING, SECTION 13,
REPLACING PARTS.
Unpacking
1.6 Remove the appliance from its packaging, and check that it
is complete and undamaged.
Put the loose ceramic parts to one side so that they are not
damaged during installation.
2. Installation of the Appliance
2.1 There are 2 methods of installation:
6a. Edge finish Installation.
6b. Installation with a decorative front.
Carefully read the relevant section for the installation
method required.
3. Flue Assembly
3.1 See Site Requirements, Section 2, Flue Options.
TAKE CARE WHEN MARKING OUT FOR THE FLUE AS
IT IS DIFFICULT TO MOVE AFTER INSTALLATION. IF A
RESTRICTOR IS REQUIRED FIT THIS BETWEEN THE
SMALL OUTLET SPIGOT AND THE AIR DUCT, SEE
DIAGRAM 1. REFER TO TECHNICAL SPECIFICATIONS
FOR RESTRICTOR SIZE.
1
3.2 A 152mm (6") diameter hole in the wall is required to install
the flue. This can be achieved by using either:
a) Core drill
b) Hammer and chisel
3.3 Drill small holes around the circumference when using
method b). Make good both ends of the hole.
3.4 Allow enough room either above or to the side of the
appliance to assemble the flue on top.
3.5 Assemble a horizontal flue in the following order:
— Vertical section
— 90° elbow
— Horizontal plus terminal
3.6 Support the opening of a masonry installation with a lintel.
3.7 Only the horizontal terminal section can be reduced in size.
To find the length:
3.8 Measure from the outside of the wall to the stop on the
90° elbow.
3.9 Add 10mm to the outlet end.
3.10 Measure from the edge of the slots closest to the wall.