Riva2 600 Balanced Flue Installation Instructions

18
Installation Instructions
Masonry Installation
8.12 Please note this appliance has been primarily designed for
studwork applications. However, there are circumstances
where the appliance could be installed in a block or
brickwork fireplace using different methods and materials for
the final effect.
THIS VOID MUST BE VENTED TO PREVENT HEAT
BUILD UP AROUND THE APPLIANCE.
8.13 This appliance is not suitable for installation onto a
combustible wall. Remove all combustible material from the
area shown, see Diagram 7.
8.14 Create a Builders Opening in chimney breast to the required
size, see Diagram 8. Ensure that the clearances to
combustible materials is maintained.
8.15 In addition to constructing the Builder's Opening to the
required size each side must have a high vent of 200cm
2
to
allow convection air to travel around the product.
The high vents should be within the 500mm gap above.
Site Requirements
MINIMUM
CLEARANCES
TO NON
COMBUSTIBLE
MATERIAL
7
400mm
10mm
225mm
12mm
10mm
50mm
150mm
50mm
50mm
Minimum of 500mm
- this dimension can
only be increased,
not reduced.
Chimney Breast
Ideal position for
a register plate -
if being used.
Ideal Masonry Installation with Flue Renovation Kit
Adjustable
ue length
8
Ventilate as
close to the top
of the void as
possible*
*BOTH SIDES MUST BE VENTILATED