Site Requirements
Installation Instructions
2c
10.0m
MAX
0.25m
2.5m
0.5m
MIN
Nat Gas 1.5m
LPG 2.0m
MIN
3D. Top Flue Vertical Offset
Kit (8530/8530AN)
3.4 Used with kit 8524. A minimum rise of 500mm (191/2) is
required to the first bend, see Diagram 2c.
4. Optional Extra Flue Lengths and Bends
All flue components are 150mm diameter (6")
NOMINAL
LENGTH
ACTUAL
LENGTH
STAINLESS
FINISH
ANTHRACITE
FINISH
200mm 140mm 8527 8527AN
500mm 440mm 8528 8528AN
1000mm 940mm 8529 8529AN
40° Bend N/A 8507 8507AN
90° Bend N/A 8508 8508AN
NOTE: The following areas need careful consideration.
a) Terminal positions
b) Flue supports
c) Weatherproofing
d) Fire precautions
For all the above options, local and national codes of
practice must be adhered to.
5. Chimney Renovation Kit (928-315)
Details of the Chimney Renovation Kit are available in the
separate installation instructions - PR2073 Chimney
Renovation Kit instructions.
6. Gas Supply
THIS APPLIANCE IS INTENDED FOR USE ON A GAS
INSTALLATION WITH A GOVERNED METER.
6.1 Before installation, ensure that the local distribution
conditions (identification of the type of gas and pressure)
and the adjustment of the appliance are compatible.
6.2 Ensure that the gas supply is capable of delivering the
required amount of gas and is in accordance with the rules
in force.
6.3 Soft copper tubing can be used to install the appliance. Soft
soldered joints can be used externally of the appliance but
must be restricted to the area shown in Diagram 3.
3
75mm
6.4 This appliance is supplied complete with a factory fitted
isolation device incorporated into the inlet connection, no
further isolation device is required.
6.5 All supply gas pipes must be purged of any debris that may
have entered, prior to connection to the appliance.
6.6 The gas supply enters through the silicone panel located on
the LEFT-HAND side on the rear of the outer box. Slit with a
sharp knife prior to passing the supply pipe through.
6.7 The gas supply must be installed in a way that does not
restrict the removal of the appliance for servicing and
inspection.