12. Primary Aeration Plate
NOT ALL MODELS HAVE AERATION PLATES. REFER
TO TECHNICAL SPECIFICATIONS, PAGE 12.
12.1 Remove the Main Burner as described in Replacing Parts
Section 5.
12.2 Remove the 2 fixing nuts and slide the plate off the venturi.
12.3 Replace with the correct size plate and secure with the nuts.
Ensure the lower edge of the plate is located over the
venturi flange, see Diagram 26.
26
13. Changing Between Gas Types
In order to change between gas types, it will be necessary
to change the pilot and main injector:
Contact your Gazco retailer for further information.
A kit of parts is available for this. Always quote the Model
number and Serial number when ordering any spare parts.
14. Debris Area Access
14.1 Remove the frame from the appliance by referring to the
separate instructions supplied with the front.
14.2 Remove the glass frame, see Section 2 and the fuel bed
components. Place carefully to one side.
14.3 Remove the baffle and liners, see Section 4.
14.4 Remove the main burner, see Section 5.
14.5 Undo the 2 screws on the back of the convector air panel,
see Diagram 27.
27
Screws
14.6 Pull the top of the air panel forwards to release, then tilt the
bottom edge upwards into the firebox to remove.
14.7 Undo the 2 screws to remove the debris access plate,
see Diagram 28.
28
Screws
14.8 Clean out any debris.
14.9 To replace the convector air panel:
Angle the top edge of the panel up and under the lip at the
back of the firebox.
Clip the panel into place and secure with the 2 previously
removed screws.