Riva2 600 600HL Conventional Flue Installation Instructions
32
Servicing Instructions - Replacing Parts
1. General
1.1 All main components can be replaced without removing the
appliance from its installation.
IT IS ESSENTIAL THAT THE GAS SUPPLY TO THE
APPLIANCE IS TURNED OFF AT THE ISOLATION
DEVICE BEFORE PROCEEDING FURTHER.
1.2 It will be necessary to remove the complete burner module
before any of the components can be serviced.
1.3 Make sure the appliance and surrounds are cool before
cleaning.
2. Removing the Glass Frame
2.1 Remove the glass frame by removing the 2 side trims, see
Diagram 1. These are held on by magnets.
1
2.2 Lift out the bottom slotted trim, see Diagram 2.
Note the orientation of the metal shield for reassembly.
2
2.3 Disconnect the battery lead from the battery pack attached
to the lower slotted trim, see Diagram 3.
3
2.4 Remove the screws at the base of the glass frame,
see Diagram 4 A.
4
A A
B
A
Riva2 600 only
2.5 Pull up the handle at the front, see Diagram 4 B.
2.6 Whilst supporting the top, lift the glass frame using the
handle, up and over the lower edge, see Diagram 5.
5
2.7 Remove the logs and Embaglow and place on a dry, clean
surface.
When refitting the glass frame ensure that the rope seal
on the back of the frame is intact.
2.8 To replace the glass frame, position so the hooks on the
back of the frame fit over the side pins, see Diagram 5.
2.9 Push the handle down.
2.10 Replace the screws. As the screws are tightened the glass
frame is pulled down against the hooks and forms a seal.
Replace ALL of the securing screws ensuring that a
screw is present in all fixing slots except centre bottom.
This is left empty.
UNDER NO CIRCUMSTANCES SHOULD THE
APPLIANCE BE USED IF ANY OF THE GLASS
FRAME RETAINING SCREWS ARE LOOSE OR
MISSING.
2.11 Connect the battery lead to the battery pack attached to the
lower slotted trim.
PLEASE ENSURE NO WIRES ARE TRAPPED
BEFORE REPLACING THE LOWER SLOTTED
TRIM. THE LEADS ARE EASILY DAMAGED.
2.12 Replace the lower trim.